IR.20-150
5
5. Electrical connection
Observe the following points when connecting the egg counting system:
1.
Use low voltage cables for electrical connection of the egg counter
(max. length 100m).
2.
Connect the egg counter according to the instructions in Fig. 2.
3.
Mount the cables so that they cannot be damaged.
4.
Ensure that cables can be easily replaced in the event of a
malfunction.
5.
Separate high/low voltage cables by mounting them in separate cable
channels.
6.
If metal cable channels are used ground them.
7.
Seal all gland nuts to prevent the entry of moisture.
Caution!
Apply power only after all the cables have been connected correctly.
Observe the regulations of the local electricity company.
Limit the length of the signal cables as much as possible; avoid
crossing high/low voltage cables.
BL
WH
24Vdc
30mA
PULSE/10 or 12
PULSE/1
RD
GN
RD = Red
BL = Black
GN = Green
WH = White
Fig. 2: Electrical connection egg counter (viewed from above)