eYeGrow
Pig group weigher
MANUAL
ST
U
4004
Page 1: ...eYeGrow Pig group weigher MANUAL STU4004...
Page 2: ...e original English version of this manual produced by PigTek For the latest information about product installation and operation please contact the customer service dept and or the technical service d...
Page 3: ...ged products or goods costs of transportation lost sales lost orders lost income increased overhead labor and incidental costs and operational inefficiencies Some jurisdictions prohibit limitations on...
Page 4: ...ling the eYeGrow 2 3 1 Mount the eYeGrow 2 3 2 Connect the eYeGrow and Switch 5 port 4 3 3 Scan the IP adresses of the eYeGrow 5 4 Using the eYeGrow 6 4 1 Sensor Settings 6 4 2 Working with the overvi...
Page 5: ...and animals Example of a practical application of the described functionality Calculation example Before installing and commissioning the eYeGrow read the safety instructions provisions and conditions...
Page 6: ...d 7 1 2 ft 2 3m above the pen Animals are weighed from 88 18 lbs 40 kilograms The software starts showing measurements between 88 18 and 110 23 lbs 40 and 50 kilograms Install the eYeGrow as follows 1...
Page 7: ...ow Example configurations are shown below NOTES Kits can be assembled with or without the adjusting flats and at any desired angle from 0 to 90 degrees to help you achieve the optimal 7 55 ft height f...
Page 8: ...nd connect 24V DC cables to the next eYeGrow box 2 Open the Switch 5 port and connect the 24V DC cable to the first eYeGrow box 3 Connect each eYeGrow box with an ethernet cable to the Switch 5 port 4...
Page 9: ...m 2 Check the MAC Address on the eYeGrow camera box 00 19 B8 02 xx xx and match the IP address to the MAC Address 3 Go to the internet browser and enter the IP address of the camera The browser will o...
Page 10: ...average growth yesterday Readings today Readout of the number of readings today Uniformity Readout of the percentage how many pigs meets the average weight 10 10 Standard deviation Readout of the sta...
Page 11: ...measured data from the start of the rearing batch Update table and graph Set the From and To date and click Update to update the data in the graph and table Download graph Open the Chart context menu...
Page 12: ...sor to restart the sensor Cleaning of dust fly faeces has been undertaken once per rearing batch using a streak free screen cleaner and microfibre cloth Use the correct cleaning products to avoid scra...
Page 13: ...ation speed Max 100 Mb Ethernet wired Cat 5 max 100 meter Housing Plastic housing ABS UL94 V 0 Protection class IP54 Dimensions l w h 300 240 140mm Weight unpacked 2 4kg Ambient climate Operating temp...
Page 14: ...provisions of the 1 Low voltage directive 2014 35 EU according to NEN EN IEC 61010 1 2010 2 EMC directive 2014 30 EU Emission according to NEN EN IEC 61000 6 3 2007 Immunity according to NEN EN IEC 61...