IMPORTANT SAFEGUARDS

Read all instructions carefully, even if you feel you are quite familiar with this type of 
appliance. When using electrical appliances, in order to reduce the risk of fire, electric shock, 
and/or injury, these basic safety precautions should always be followed:

1. All wiring must be done by a licenced electrician as on-site warranty may be voided 
if proof cannot be provided. This ceiling fan MUST be installed by a Qualified Electrical 
Contractor in accordance with the local regulations, and all local, state and national 
electrical codes. Any alterations or additions to building wiring must be completed by a 
licensed electrical contractor, or person authorised by legislation to work on the fixed wiring 
of any electrical installation.
2. The fan must be connected to a 240V AC 50Hz power supply.
3. All electrical work must only be undertaken after disconnection of the power by removing 
fuses or turning off the circuit breaker, to ensure all pole isolation of the electrical supply.
4. The fan must be earthed.
5. The fan must be installed so that the blades are at least 2.1 metres above the floor.
6. The ceiling fan weight is max. 6 kg. The structure that the ceiling fan is mounted to must 
be capable of supporting a weight of at least 45 kg. The fixing must be able to support the 
moving weight of the fan and must not twist or work loose.
7. Make sure that the installation site will not allow the rotating fan blades to come into 
contact with any object and that there is enough space from the blade tip to the wall or 
ceiling. Please note that insufficient clearance distances might cause wobbling and the 
bigger this clearance is the better the airflow from your fan will be.
8. This product can be installed in a position where it is covered or enclosed al fresco areas 
and there is a minimum clearance of 1.50 m from the blade tip to all edges of the roof or 
positions where could be exposed to water, moisture or other dangerous external elements.
9. DO NOT connect the fan motor to a dimmer switch. This may give an unsatisfactory 
performance (motor hum) and cause damage to the motor and/or controller. Use ONLY the 
provided remote control.
10. This appliance is not intended for use by young children or infirm persons without 
supervision.
11. Young children should be supervised to ensure that they DO NOT play with the appliance.
12. It is NOT recommended that ceiling fans and gas appliances be operated in the same 
room at the same time.
13. The fan must be turned off and stopped completely before reversing the fan direction. 
This will prevent any damage to the motor of the fan or controller.
14. Do not insert anything into the fan blades whilst they are spinning. This will damage the 
blades and upset the balance of the fan causing the unit to wobble.
15. After the fan is completely installed make sure that all base and fan blade fixings are 
secured and tightened to prevent any problems.
16. Because of the fan’s natural movement, some connections may loosen. Check the support 
connections, brackets and blade attachments twice a year to make sure they remain 
secured. If any are loose, tighten.
17. If unusual oscillating movement is observed, immediately stop using the ceiling fan and 
contact the manufacturer, its service agent or suitably qualified persons.
18. The replacement of parts of the safety suspension system device shall be performed by 
the manufacturer, its service agent or suitably qualified persons.

1

Summary of Contents for CFFCEM4BL

Page 1: ...Eco Motion DC DC Installation Manual...

Page 2: ...ceiling Please note that insufficient clearance distances might cause wobbling and the bigger this clearance is the better the airflow from your fan will be 8 This product can be installed in a positi...

Page 3: ...ct and keep it away from children If you think batteries might have been swallowed or placed inside any part of the body seek immediate medical attention Call the Poisons Information Centre on 13 11 2...

Page 4: ...e is a minimum clearance of 1 50 m from the blade tip to all edges of the roof or positions where could be exposed to water moisture or other dangerous external elements 4 Secure the hanging bracket t...

Page 5: ...g this fan E L N L in L out Power Supply Live Wire Brown Power Supply Neutral Wire Blue Ground Wire Yellow Green Live Wire Brown Neutral Wire Blue Ground Wire Yellow Green Double pole disconnection sw...

Page 6: ...2 3 Make location point for J hook 3mm Hole Dia 8mm Deep 50mm Ceiling Ceiling E xplosive hook positioning Take out Loosen Remove the screws from the canopy Separate the bracket from the canopy Rotate...

Page 7: ...6 Installation finish Fasten the bracket on the ceiling by expansion screw fasten the J hook 2 5 Drill hole 2 4 2 6 Hole Dia 8mm Deep 50mm ceiling ceiling ceiling...

Page 8: ...7 1 2 3 Remove the blade holders Turn motor upside down Bladeholder mounting plate Fan blade Aligning the screw hole of blade and blade holder Remove screws...

Page 9: ...Install the blades and tighten the screws Installation plate blade Make sure all the blades are smooth after installation 3 2 Remove the screws on the yoke Remove Enlarged view Downrod Canopy Install...

Page 10: ...ctor screw installation Cottern pin a downrod canopy 2 3 Fix with nut b c d 4 5 Align at the Downrod Align at the Downrod Enlarged drawing downrod safety wire N Wire L Wire E arth wire Place downrod t...

Page 11: ...the mounting bracket Tighten the screw 1 b Rotate the fan assembly so that the groove on the ball engages the ridge in the mounting bracket Place Groove Lug Wire rope installation Attach the safe wir...

Page 12: ...holes on the canopy match the holes in the mouthing bracket 1 Fan Input voltage AC 2 20V 240V 50Hz E arth wire AC I N L Brown AC I N N Blue E arth wir Yellow Green Mix Insert Tighten Wiring cap use me...

Page 13: ...e cannopy are tightened The installation is complete 2 Tighten Rotate the canopy to align the holes and secure the canopy to the mounting bracket tighten the screws Tighten Base plate Insert 1 Base Pl...

Page 14: ...rating at low speeds WOBBLE Ceiling fans are designed to move during operation because they are not generally rigidly mounted Movement of a couple of centimetres is acceptable for safe operation Balan...

Page 15: ...y remove the pre assembled receiver from the connection and replace with remote control receiver in the accessory pack 3 Install the motor housing back and secure with screws 4 Follow the same install...

Page 16: ...ntrol a Please check the battery to ensure it has sufficient power and has been inserted correctly and aligns with the positive and negative terminals or b Please check if there are any other similarl...

Page 17: ...the remote has paired sucessfully complete process needs to be finished within 10 seconds FUNCTIONS OF TRANSMITTER Note light buttons are not functional on this model as the fan does not have a light...

Page 18: ...and wiring on premises Fan keeps beeping but will not start Loose wire connections or plugs to fan receiver Check wire connections and ensure plugs are positively connected Fan wobbles A Screws on do...