10
AFTER INSTALLATION
WOBBLE:
The fan blades have been adjusted in the factory to minimize any wobble.
NOTE: CEILING FANS TEND TO MOVE DURING OPERATION DUE TO THE FACT THAT THEY ARE
MOUNTED ON A RUBBER GROMMET. IF THE FAN WAS MOUNTED RIGIDLY TO THE CEILING IT
WOULD CAUSE EXCESSIVE VIBRATION. MOVEMENT OF A FEW CENTIMETRES IS QUITE
ACCEPTABLE AND DOES NOT SUGGEST ANY PROBLEM.
TO REDUCE THE FAN WOBBLE: PLEASE CHECK THAT ALL SCREWS WHICH SECURED THE
MOUNTING BRACKET AND DOWN ROD ARE SECURE.
BALANCING A WOBBLING CEILING FAN:
For your convenience, a Balancing Kit is included; please follow this procedure when balancing the fan:
1) Install fan without light dome before balancing the fan.
2) Define the base plate into four areas (point A, B, C & D).
Use one weight from the balance kit to lightly stick on the
edge of the base plate (say point A), if the wobble
worsens, then take off the balance kit and lightly stick it
on the opposite side (say point B); if the wobble is worse,
then go to the adjacent point C or D, if the wobble gets
better, then securely stick on the weight at this location on
the base plate.
3) After balancing the fan, assemble the light dome to the
light base.
NOISE:
When it is quiet (especially at night) you may hear occasional small noises. Slight power fluctuations and
frequency signals superimposed in the electricity for off-peak hot water control, may cause a change in fan
motor noise. This is normal. Please allow a 24-hour “breaking -in” period, most noises associated with a new
fan disappear during the time. The manufacturer’s warranty covers actual faults that may develop and NOT
minor complaints such as hearing the motor run – All electric motors are audible to some extent.
CARE AND CLEANING
1) Periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth to
avoid scratching the paint finish. Please turn off electricity power when you do so.
2) Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the
possibility of an electrical shock.
3) Motor has permanently lubricated ball bearing. No need to oil
NOTE: Always turn off the power and disconnect the female plug 1 and male plug 1 before attempting to clean
your fan.
Summary of Contents for LD-0003-10/CH/GS/E27
Page 3: ...3 Figure 1 ...
Page 5: ...5 Figure 3 ...
Page 12: ...12 Abbildung 1 ...
Page 14: ...14 Abbildung 3 ...
Page 21: ...21 Figure 1 ...
Page 23: ...23 Figure 3 ...
Page 30: ...30 FIGURA 1 ...
Page 32: ...32 Figura 3 ...
Page 39: ...39 figura 1 ...
Page 41: ...41 Figura 3 ...
Page 48: ...48 AFBEELDING 1 ...
Page 50: ...50 afbeelding 3 ...