Specifications: 

 

 

Troubleshooting: 

 

The following overview serves as an aid for quick troubleshooting. If you are unsure, contact the 
manufacturer, the dealer or the corresponding specialist personnel. 

 

 

 

If the specified corrections have not led to success, please contact our service staff. The contact 
details can be found at www.musicstore.de 

 
 

 

Model 

Single C 

Directional characteristic 

Cardioid 

Frequency range 

30 Hz – 18 kHz 

Sensitivity 

23,3 mV/Pa // 0 dB = 1 V/Pa at 1 kHz 

Equivalent inherent sound 

20 dB (A-weighted) 

Max. sound pressure 

135 dB at 1% THD @ 1 kHz 

Power supply 

9-52 V Phantom power 

Connection 

XLR 3 pin 

Symptom 

Troubleshooting 

No tone 

Check the cable for damage (cuts, extreme kinks, 
etc.) and replace if necessary. 
Check the wiring. Connectors must be fully 

inserted and snap into place! 
Check if the 48V phantom power is switched on at 

the console/interface. 
Check the setting of the preamplifier on the 
console/interface/etc. 
Arm microphone in your DAW (Digital 
Workstation) or activate direct monitoring 
Microphone may need to be levelled. Please read 

the software manual of the respective DAW. 

Delayed tone 

Change the buffer size in the DAW settings. The 

lower the number, the lower the latency. (Note: 
with a low buffer size, the machine requires higher 

performance. Depending on the computer, this 
can lead to higher performance losses). 

 

For more 

information, please refer to the manual of each 
digital audio workstation. 

Summary of Contents for Single C

Page 1: ...from the manufacturer Always make sure that the grounding of the device is maintained Only use the supplied power cables and always maintain the earthed protective contacts on the side Make sure that the sockets used have a properly functioning protective earth Failure to do so may result in fire or death due to electric shock DANGER For babies and children Dispose of or store any packaging materi...

Page 2: ...isconnect the device from the power source in order to minimize danger Never pull the cable while phantom power is active Hint Condensation To avoid condensation in the unit the unit should adapt to the ambient temperature before commissioning Hint Unwanted odours A new product can sometimes lead to unwanted odours This reaction is normal and disappears after a few minutes Hint Damage to loudspeak...

Page 3: ...ctions in the manual The lightning warns you of dangerous voltage accessible from the outside A connection to any terminal marked with this symbol may only be made with a ready made cable that complies with the manufacturer s recommendations or with cables installed by qualified personnel Only suitable for indoor use Read the manual Please read and follow the warnings and recommendations carefully...

Page 4: ...ichael Sauer WEEE Reg No DE 41617453 Tel 49 221 8884 0 Fax 49 221 8884 2500 info musicstore de Intended use The product FAME Audio Single C was designed for use as a microphone The device may only be used for this purpose and in accordance with the operating instructions Other purposes as well as operation under other operating conditions are expressly not intended and can lead to damage to proper...

Page 5: ...nt and use This small diaphragm condenser microphone has a 3 pin XLR connector and comes with a matching windscreen Due to its acoustic properties it can be used to pick up overheads and acoustic instruments Commissioning All connections of the device should be made before switching on Only use high quality undamaged and as short cables as possible for the connections Configuration of the 3 pin XL...

Page 6: ...Omnidirectional Since the omnidirectional characteristic has no extinctions due to the design of the microphone sound from all directions can be picked up almost uniformly Example application 2 Cardioid Sound hitting the rear is extinguished dampened by the cardioid characteristic The focus here is on the direct signal FAME Audio Single C Cardioid characteristic The FAME Audio Single C is characte...

Page 7: ...in Symptom Troubleshooting No tone Check the cable for damage cuts extreme kinks etc and replace if necessary Check the wiring Connectors must be fully inserted and snap into place Check if the 48V phantom power is switched on at the console interface Check the setting of the preamplifier on the console interface etc Arm microphone in your DAW Digital Workstation or activate direct monitoring Micr...

Page 8: ...the packaging components after use properly Disposal of packaging Ensure that paper packaging plastic materials etc are separately recycled Observe the corresponding disposal instructions on the packaging Disposal of batteries Batteries do not belong in the garbage Please keep batteries in accordance with the official collection points or disposal stations in accordance with the specifications Dis...

Page 9: ...ENGLISH MS ID REC0004720 000 02 2019 Notes ...

Reviews: