Model
MS Pro 38D-S
Principle
Dynamic
Polar Pattern
Hypercardioid
Frequency
50 - 16000 Hz
Sensitivity
-56dB±3dB (0 dB=1 V/Pa at 1kHz)
Impedance
19Ω±20% at 1KHz
On/Off-Switch
Yes
Symptom
Troubleshooting:
No Sound
Check the cable for damage (cuts, extreme kinks,
etc.) and replace it if necessary.
Check the wiring. Plugs must be fully inserted and
locked in place!
Check that the 48V phantom power on the
console/interface is switched on.
Check the preamplifier setting on the
console/interface/etc.
Delayed Sound
Change the buffer size in the DAW settings. The
lower the number, the lower the latency. (Note:
with a low buffer size, the computer needs more
power. Depending on the computer, this can lead
to higher performance losses). For more
information, please refer to the manual of the