![Famco MONT72 Series User Manual Download Page 28](http://html1.mh-extra.com/html/famco/mont72-series/mont72-series_user-manual_3298049028.webp)
Shenzhen Hpmont Technology Co., Ltd.
Chapter 4 Electrical Installation
MONT72 Series User Manual V1.0
- 19 -
4.3.2
Power Terminal Wiring
During the test run, please confirm whether the elevator is going up when the command is up. If the
elevator is down, reverse the set value of F00.08 (Running direction selection). The power terminal
wiring is shown in Table 4-5.
Contactor, MCCB, power cord, motor line, grounding wire selection, see section 4.2.1 Wiring
Specifications of Input and Output, page 15.
For the selection of braking resistor, see section 2.6 Resistor Selection, page 11.
Table 4-5 Power terminal wiring
FA
FB / FD / FE
FC / FF
Note: Single-phase input models can connect single-phase input power to any two phases of L1, L2, L3.
L1 L2 L3 (+) (-) BR
U
V
W
PE
Brake
resistor
Power
grounding
Optional EMI filter
Optional AC reactor
City power supply
MCCB
Contactor
L1 L2 L3
(+) (-) BR
U
V
W
PE
Brake
resistor
Power
grounding
P1
DC
reactor
Optional AC reactor
City power supply
MCCB
Contactor
Optional EMI filter
L1 L2 L3 (+) (-) BR
U
V
W
PE
Brake
resistor
Power
grounding
Optional EMI filter
Optional AC reactor
City power supply
MCCB
Contactor
4
Summary of Contents for MONT72 Series
Page 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Page 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Page 7: ......
Page 9: ......
Page 15: ......
Page 43: ......
Page 81: ......
Page 99: ......