Appendix A Parameters
HD3N-L Series User Manual V1.0
- 69
-
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F12.06
DI6 function
9: Run contactor feedback
input (CSM)
10: Brake feedback input
(BSM)
11 - 14: Unused
15: Motor overheat input (OH)
16: Fault reset input (RST)
17 - 33: Unused
34: External fault (EXT)
6
1
×
F12.07
DI7 function
0
1
×
F12.08
DI8 function
0
1
×
F12.13
Filter time of multi-speed
terminal
0.000 - 2.000s
0.010s
0.001s
×
F12.15
DO1 function
0: Unused
1: Controller is ready
2: Running (RUN)
3: Zero-speed running
4: Zero-speed
5: Run contactor output
control
6: Brake output control
7: FDT1
8: FDT2
9: Speed within signal (FAR)
10: Up signal output
11: Down signal output
12: Under-voltage
13: Unused
14: Controller fault
15 - 19: Unused
2
1
×
F12.16
DO2 function
3
1
×
F12.17
RLY1 function
14
1
×
F12.18
RLY2 function
0
1
×
F12.21
Output terminal logic setting
Bit0 - Bit1: DO1 - DO2 logic
setting
Bit2 - Bit3: RLY1 - RLY2 logic
setting
0: Positive logic
1: Negative logic
0
1
○
F13: Analogue I/O Terminal Parameters (on pages 39 - 40)
F13.00
AI function
0: Unused
1: Speed setting
0
1
×
F13.04
AI bias
-100.0 - 100.0%
0.0%
0.1%
○
F13.05
AI gain
-10.00 - 10.00
1.00
0.01
○
F13.06
AI filter time
0.01 - 10.00s
0.05s
0.01s
○