background image

15

cord is too short, have a qualified electrician in-

stall an outlet near the appliance. 

Before installing the hood, check that the electrical 
mains power supply corresponds with what is report-
ed on the identification plate located inside the hood.

The socket used to connect the installed equipment 
to the electrical power supply must be within reach: 
otherwise, install a mains switch to disconnect the 
hood when required.

Any changes to the electrical system must be carried 
out by a qualified electrician. 

The maximum length of the flue fastening screws 
(supplied by the manufacturer) must be 1/2" (13 mm).
Use of non-compliant screws with these instructions 
can lead to danger of an electrical nature.

Do not try to solve the problem yourself in the event 
of equipment malfunction, but contact the Dealer or 
an authorised Servicing Department for repairs.

When installing the hood, disconnect the 

equipment by removing the plug or switch-

ing off the main switch.

WARNING: To Reduce The Risk Of Fire Or Electric 

Shock, Do Not Use This Fan With Any Solid-State 

Speed Control Device

WARNING: NOT SUITABLE FOR USE WITH SOL-

ID-STATE SPEED CONTROLS

FUMES DISCHARGE SAFETY

Do no connect the equipment to discharge 

pipes of fumes produced from combustion 

(for example boilers, fireplaces, etc.).

Before installing the hood, ensure that all standards in 
force regarding discharge of air out of the room have 
been complied with.

To reduce risk of fire and to properly exhaust air, 

be sure to duct air outside – Do not vent exhaust 

air into spaces within walls or ceilings or into at-

tics, crawl spaces, or garages.

WARNING: TO REDUCE THE RISK OF FIRE, USE 

ONLY METAL DUCTWORK.

USER WARNINGS

These warnings have been drawn up for 

your personal safety and those of others. 

You are therefore kindly asked to read the 

booklet carefully in its entirety before using the 

or cleaning the equipment.

The Manufacturer declines all responsibility for 

any damage caused directly, or indirectly, to per-

sons, things and pets as a consequence of failing 

to comply with the safety warnings indicated in 

this booklet.

It is imperative that this instructions booklet is 

kept together with the equipment for any future 

consultation.

If the equipment is sold or transferred to another per-
son, make sure that the booklet is also supplied so 
that the new user can be made aware of the hood's 
operation and relative warnings. 
After the stainless steel hood has been installed, it 
will need to be cleaned to remove any residues re-
maining from the protection adhesive as well as any 
grease and oil stains which, if not removed, can cause 
irreversible damage to the hood surface. To properly 
clean the unit, the manufacturer recommends using 
the supplied moist wipes, which are also available 
sold separately. 
Insist on original spare parts.

State of California Proposition 65 Warning

(US only) 

WARNING 

This product contains chemicals known to the State 
of California to cause cancer and birth defects or oth-
er reproductive harm. 
For more information go to www.P65Warnings.ca.gov

INTENDED USE

The equipment is solely intended to be used to 

extract fumes generated from cooking food in 

non-professional domestic kitchens: any other 

use is improper. Improper use can cause damage 

to persons, things, pets and exempts the Manu-

facturer from any liability.

The equipment can be used by children over the 
age of 8 and by persons with reduced physical, 
sensory and mental abilities, or with no experience or 
knowledge, as long as they do so under supervision 
or after having received relative instructions regarding 
safe use of the equipment and understanding of the 

Summary of Contents for Pyramid FOPYR36W12OS

Page 1: ...eus Outdoor Outdoor FOPYR36W12OS FOPYR42W12OS FOPYR48W12OS FOZEU36W12OS FOZEU42W12OS FOZEU48W12OS INSTRUCTIONS BOOKLET INSTRUCTIONS BOOKLET EN MODE D EMPLOI FR MANUAL DE INSTRUCCIONES ES LIBRETTO ISTR...

Page 2: ...1 m m 1711 16 450 mm 49 1 2 1257 mm 29 13 16 757 mm 311 2 800 mm 19 11 16 500 mm 11 13 16 300 mm 18 457 mm 4 1 2 114 mm ZEUS 36 FOZEU36W12OS 120V 60HZ 850W EN cable length 5 0ft 1 5m FR longueur de c...

Page 3: ...257 mm 29 13 16 757 mm 311 2 800 mm 19 11 16 500 mm 11 13 16 300 mm 18 457 mm 4 1 2 114 mm 415 8 1058 mm 415 8 1058 mm ZEUS 42 FOZEU42W12OS 120V 60HZ 540W EN cable length 5 0ft 1 5m FR longueur de c b...

Page 4: ...7 mm 29 13 16 757 mm 311 2 800 mm 19 11 16 500 mm 11 13 16 300 mm 18 457 mm 4 1 2 114 mm 4715 16 1217 mm 4715 16 1217 mm ZEUS 48 FOZEU48W12OS 120V 60HZ 850W EN cable length 5 0ft 1 5m FR longueur de c...

Page 5: ...114 mm 11 1 16 281 mm 31 1 2 800 mm 9 7 8 2 5 1 m m 49 1 2 1257 mm 29 13 16 757 mm 1711 16 450 mm 311 2 800 mm PYRAMID 36 FOPYR36W12OS 120V 60HZ 850W EN cable length 5 0ft 1 5m FR longueur de c ble 5...

Page 6: ...1 16 281 mm 31 1 2 800 mm 9 7 8 2 5 1 m m 49 1 2 1257 mm 29 13 16 757 mm 1711 16 450 mm 311 2 800 mm PYRAMID 42 FOPYR42W12OS 120V 60HZ 850W EN cable length 5 0ft 1 5m FR longueur de c ble 5 0ft 1 5m...

Page 7: ...1 2 800 mm 9 7 8 2 5 1 m m 49 1 2 1257 mm 29 13 16 757 mm 1711 16 450 mm 311 2 800 mm 4715 16 1217 mm PYRAMID 48 FOPYR48W12OS 120V 60HZ 850W EN cable length 5 0ft 1 5m FR longueur de c ble 5 0ft 1 5m...

Page 8: ...ui remplacent toutes les recommandations stipul es dans le pr sent document ES Medidas instalaci n La altura de montaje recomendada desde la su perficie de cocci n hasta el fondo de la campana se indi...

Page 9: ...yau d aspiration 3 ES Fijaci n de la campana 1 instalaci n de la v lvula antirretorno 2 y montaje del tubo de aspiraci n 3 IT Fissaggio cappa 1 installazione valvola di non ritorno 2 e montaggio tubo...

Page 10: ...11 V3 x11 2 G H 1 OPTIONAL 3 L H 1 4 1 4 6 mm 1 4 6 mm 5 L H V5 x2 3 L 2 V4 x3 4 EN Flue assembly optional FR Montage de la chemin e optionnel ES Montaje de la chimenea opcional IT Montaggio camino op...

Page 11: ...i remplacent toutes les recommandations stipul es dans le pr sent document ES Medidas instalaci n La altura de montaje recomendada desde la su perficie de cocci n hasta el fondo de la campana se indic...

Page 12: ...uyau d aspiration 3 ES Fijaci n de la campana 1 instalaci n de la v lvula antirretorno 2 y montaje del tubo de aspiraci n 3 IT Fissaggio cappa 1 installazione valvola di non ritorno 2 e montaggio tubo...

Page 13: ...13 2 V3 x9 G H 1 3 1 H L 4 1 4 6 mm 1 4 6 mm 5 L H V5 x2 3 L 2 V4 x3 4 EN Flue assembly optional FR Montage de la chemin e optionnel ES Montaje de la chimenea opcional IT Montaggio camino opzionale...

Page 14: ...ation always use personal protective equipment e g Safety shoes and adopt prudent and proper conduct The installation kit screws and plugs supplied with the hood is only to be used on masonry walls in...

Page 15: ...our personal safety and those of others You are therefore kindly asked to read the booklet carefully in its entirety before using the or cleaning the equipment The Manufacturer declines all responsibi...

Page 16: ...ng process during the use of deep fryers Overheated oil can catch fire Do not leave open unattended flames under the hood Do not prepare food over an open flame under the hood Never use the hood witho...

Page 17: ...ct fumes and vapours towards the suction surface After cooking leave the hood operating until complete extraction of all vapours and odours WHICH SPEED IS TO BE SELECTED 1st speed maintains the circul...

Page 18: ...erials that can be recycled Proper disposal of these products contributes to saving valuable resources and avoid potential negative effects on personal health and the environment which may be caused b...

Page 19: ...tte NE doit PAS tre install e la remettre dans son emballage d origine et contacter le Reven deur Apr s son installation aucune r clamation ne sera accept e pour des d fauts esth tiques Pendant l inst...

Page 20: ...toutes les normes en vigueur sur l vacuation de l air l ext rieur de la pi ce sont respect es Afin de r duire le risque d incendie et d vacuer correctement l air assurez vous de faire circuler l air l...

Page 21: ...s teindre le br leur SOYEZ PRU DENT POUR VITER LES BR LURES Si les flammes ne s teignent pas imm diatement VACUER ET APPELER LES POMPIERS b NE JAMAIS SAISIR UNE PO LE ENFLAMM E Vous pourriez vous br l...

Page 22: ...dis tance d ouverture des contacts permettant la d connexion com pl te dans les conditions de la cat gorie de surtension III Ces dispositifs de d connexion doivent tre pr vus dans le r seau d alimenta...

Page 23: ...uction des filtres m talliques anti graisse voir les instructions de montage CLAIRAGE a hotte est quip e d un clairage led haute efficacit basse consommation et dur e tr s lev e en conditions d utilis...

Page 24: ...a colocar en su embalaje original y p ngase en contacto con el revendedor Una vez instalada no se aceptar ninguna recla maci n por defectos est ticos Durante la instalaci n utilice siempre equipos de...

Page 25: ...NCIA NO APTO PARA USO CON CON TROLES DE VELOCIDAD DE ESTADO S LIDO SEGURIDAD DESCARGA DE HUMOS No conecte el aparato a conductos de des carga de los humos producidos por la com busti n por ejemplo cal...

Page 26: ...MAS con una tapa ajustada una bandeja para hornear o una bandeja met li ca despu s apague el quemador TENGA CUIDA DO PARA EVITAR QUEMADURAS Si no se apagan las llamas inmediatamente EVAC E LA ZONA Y L...

Page 27: ...permita la desconexi n completa en las condiciones de la categor a de sobretensi n III Estos dispositivos de desconexi n deben preverse en la red de ali mentaci n en conformidad con las reglas de inst...

Page 28: ...ser sustituidos cada 3 4 meses en condiciones de uso normal Para sustituir los filtro de carb n activo consulte las instrucciones de montaje ILUMINACI N La campana cuenta con iluminaci n de led de el...

Page 29: ...a installata non sar accettato alcun re clamo per difetti estetici Durante l installazione utilizzare sempre mezzi di pro tezione personale es scarpe antiinfortunistiche ed adottare comportamenti prud...

Page 30: ...ti o nei soffitti nei sottotetti in spazi ristretti o nei garage AVVERTENZA PER RIDURRE IL RISCHIO DI INCEN DIO UTILIZZARE SOLO CONDOTTI METALLICI AVVERTENZE PER L UTILIZZATORE Queste avvertenze sono...

Page 31: ...a necessaria conoscenza purch sotto sorveglianza oppure dopo che le stesse abbiano ricevuto istruzioni relative all uso sicuro dell apparecchio e alla comprensione dei pericoli ad esso inerenti I bamb...

Page 32: ...completa nelle condizioni della categoria di sovratensione III Tali dispositivi di disconnessione devono essere previsti nella rete di alimentazione conformemente alle regole di installazione Il cavo...

Page 33: ...pparecchiature Elettriche ed Elettroniche e pertanto non deve essere gettato nella spazzatura indifferenziata cio insieme ai rifiuti urbani misti ma deve essere gestito separatamente cos da essere sot...

Page 34: ...34 NOTE NOTES...

Page 35: ...35 NOTE NOTES...

Page 36: ...Code 110033094 Ed 01 2022 Codice Code Matricola Serial Number Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com...

Reviews: