  WARRANTY

All FALMEC rangehoods come with a 5 year parts and labour warranty. PR Kitchens & 
Washrooms will correct, free of charge, any defects in material or workmanship for the 
period of 5 years, subject to the terms of our warranty stated below.

This  warranty  will  be  void  if  a  Falmec  range  hood  is  used  for  commercial  purposes. 
Some examples of commercial purposes but not limited to, include restaurants, cafes, 
schools and clubs.

Rangehoods  in  the  Falmec  range  (excluding  BBQ  models)  are  designed  and 
warranted “strictly” for indoor use only (household kitchen).

1. This warranty only applies for products installed by a qualified person and when 
provided with a certificate of compliance in accordance with State/Territory laws.

2. This product must be used in accordance with the manufacturer’s instructions. This 
warranty does not apply should the defect in or failure of the product be attributable to 
misuse, abuse, accident or non-observation of the manufacturer’s instructions on the 
part of the user. FALMEC appliances does not accept liability for any direct or 
consequential loss, damage or other expense caused by or arising out of any failure to 
install or use the product in accordance with the manufacturer’s instructions.

3. The warranty does not cover failures due to normal wear and tear with reasonable 
use or consumable components such as globes, filters, etc.

4. PR Kitchens & Washrooms, at its own discretion may replace or repair any defective 
component(s) to affect a repair due to any faulty workmanship and material. The 
warranty does not cover breakage of outer glass panels attributed to external damage.

5. The warranty provided is a “Repair Warranty” and in an extreme event if a repair 
cannot take place, a replacement will be provided of an equivalent current model where 
the balance of the warranty period from the original date of purchase will take effect.

6.  This  warranty  is  immediately  void  if  the  serial  or  model  number  label  is  removed, 
defaced,  serviced  or  repaired  by  a  unauthorised/unqualified  personal  or  used  for 
industrial/commercial purposes.

7. Warranty will be only provided when a proof of the original purchase is presented to 
an authorised dealer or reseller before or at the time of service.

8. This warranty does not cover any corrosion or defect as a result of the product being 
installed in an environment in which the appliance is not protected from the weather.

9. It is the responsibility of the customer to ensure the appliance is easily accessible for 
a service technician to carry out required repairs. Any obstruction prohibiting access to 
the product by building materials of any kind will be required to be removed and 
reinstalled by the customer.

10. PR Kitchens & Washrooms has a service network in all metropolitan areas and most 
regional areas. Where the warranty claim has been made outside a radius of 50km from 
any store where the product can be purchased, the customer is responsible for the cost 
of delivery to the nearest service agent or the travel cost for a technician to travel to a 
location outside the 50km radius.

PRODUCT SOLD IN AUSTRALIA ONLY

:

At PR Kitchens & Washrooms our goods come with guarantees that cannot be 
excluded under the Australian Consumer Law. You are entitled to a replacement or 
refund for a major failure and compensation for any other reasonably foreseeable loss 
or damage. You are also entitled to have the goods repaired or replaced if the goods 
fail to be of acceptable quality and the failure does not amount to a major failure.

OUTDOOR USE RANGEHOODS

Outdoor  BBQ  models  from  Falmec  are  warranted  for  use  above  barbecues  and  in 
alfresco areas with one open wall and a solid roof such as that they are not exposed to 
the elements.

Outdoor  BBQ  models  MUST  only  have  the  specified  2010  m3/hr  motor  installed  in 
conjunction with the hood.

In  the  scenario  where  the  hood  is  located  near  the  ocean  or  exposed  to  salty  air, 
regular care and cleaning of the hood is recommended to prevent any corrosion.

REMOTE MOTOR RANGE HOODS

In addition to the standard 5 years parts and labour warranty stated above the remote 
motors from the Professional series are covered for an additional 5 years as a part only 
warranty therefore giving a total coverage of 10 years. This warranty is conditional by 
the following items

If installed in coastal applications the external housing must have anti-corrosive 

coating applied. The internal fan may also require additional cleaning/washdown as a 
result of exposure to salt in the air.

Fan must be installed in a position that it will not be subjected to excessive duct 

temperatures (40˚ covers all models).

Filters must be in place within the rangehood and regularly maintained/cleaned/

replaced as needed.

SUPPORT

At PRKS we place great importance on customer satisfaction and that is why we have 
established a dedicated and experienced customer support team that you can rely on.

Should  you  ever  need  to  make  a  warranty  related  enquiry  about  your  FALMEC 
product, you can lodge the enquiry at:

AUSTRALIA

www.prkws.com 

[email protected] 

03 9700 9100

NEW ZEALAND

www.prkws.com 

[email protected]

 09 964 0400

We suggest you have the following information close at hand:

1. Model number of your product

2. A copy of your original purchase receipt

3. Address details of where the product is installed.

Any relevant pictures can be attached if lodging the claim online 

Summary of Contents for nuvola 140

Page 1: ...INSTALLATION MANUAL falmecau com Nuvola ...

Page 2: ...E REVIEW YOUR NEW ITEM TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN ADDITIONAL CHARGES ENVIRONMENTAL TIP Information on disposal for users Most of the packing materials are recyclable Please dispose of those materials through your local recycling depot or by placing them in a appropri...

Page 3: ...2 HOLE SIZES 940 1325 505 590 540 625 973 1358 925 1310 492 577 370 556 128 min 10 max 25 341 239 275 95 275 150 NUVOLA 90 32 KG NUVOLA 140 45 KG INSTALLATION WITH MOTOR ON THE HOOD ...

Page 4: ...3 HOLE SIZES 940 1325 505 590 540 625 973 1358 216 472 min 10 max 25 128 925 1310 492 577 370 246 193 144 86 95 556 640 NUVOLA 90 31 KG NUVOLA 140 44 KG INSTALLATION WITH SLIM MOTOR ...

Page 5: ...4 HOLE SIZES 940 1325 505 590 540 625 973 1358 925 1310 492 577 370 556 128 min 10 max 25 275 275 86 216 193 95 144 NUVOLA 90 24 KG NUVOLA 140 37 KG INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR ...

Page 6: ...5 HOLE SIZES 940 1325 505 590 min 10 max 25 128 540 625 973 1358 95 925 1310 492 577 150 130 NUVOLA 90 22 KG NUVOLA 140 35 KG INSTALLATION WITH REMOTE MOTOR ...

Page 7: ...6 Max 1500 mm ø9 mm MEASUREMENTS FOR INSTALLATION ...

Page 8: ... C O N T R O S O F F I T T O 2 m i n 6 0 m m min 60 mm 1 F A L S E C E I L I N G C O N T R O S O F F I T T O G 3 4 double adhesive 2 1 H H x 1 2 Cutting the plasterboard 1 inserting the supporting frame 2 PRELIMINARY OPERATIONS ...

Page 9: ...8 X Y X 1 2 Y 4 3 Ø9 mm 3 Fixing the mandatory safety chains to the ceiling PRELIMINARY OPERATIONS ...

Page 10: ...9 Open the panel remove the filters 4 and gas piston 5 1 4 2 3 2 1 4 5 PRELIMINARY OPERATIONS ...

Page 11: ...10 INLET 1 2 3 Remove the flange from the hood 1 and the motor 2 If the air outlet is upward see 3 For other directions see 4 and 5 INSTALLATION WITH MOTOR ON THE HOOD ...

Page 12: ...11 5 4 AIR 180 3 4 90 5 x 8 6 x 8 2 1 OUTLET INSTALLATION WITH MOTOR ON THE HOOD Side movement of the air exhaust ...

Page 13: ...12 120 mm x8 x4 1 3 1 2 3 6 INSTALLATION WITH MOTOR ON THE HOOD ...

Page 14: ...13 7 1 2 8 INSTALLATION WITH MOTOR ON THE HOOD Fixing the motor support brackets 7 Positioning the motor on the support frame 8 ...

Page 15: ...14 ø 15 950 m3 h 1100 m3 h 150mm 1 2 3 9 INSTALLATION WITH MOTOR ON THE HOOD Fitting the suction pipe and electrical connection 9 ...

Page 16: ...15 2 1 1 2 Remove the flange from the hood 1 Detach pre cut elements and position the slim motor bracket SLIM MOTOR ...

Page 17: ...16 A I R 145 5 S L I M L M 2 1 3 V 1 x8 4 V2 x4 3 Fixing the motor support brackets 3 SLIM MOTOR INSTALLATION ...

Page 18: ...17 1 2 L M H G SLIM 217mm 87mm 800 m3 h 1 2 3 4 5 Positioning the motor on the support frame 4 Fitting the suction pipe and electrical connection 5 SLIM MOTOR INSTALLATION ...

Page 19: ...18 120 mm AIR AIR 3 4 2 2 V2 x4 V1 x 8 120 mm 3 V1 x8 4 V2 x4 2 1 Remove the lange from the hood 1 Fixing the brackets onto the rectangular connection 2 INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR ...

Page 20: ...19 1 2 L CT M H G 3 1 217mm 87mm CUE 2 4 Positioning the rectangular connection on the support frame 3 Fitting the suction pipe 4 INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR ...

Page 21: ...20 1 2 150mm 200 mm KAC L 396 N O V A L V E O P T I O N A L 1 2 Fitting the non return valve 1 REMOTE MOTOR INSTALLATION ...

Page 22: ...21 F 1 2 REMOTE MOTOR REMOTE EXTERNAL MOTOR 3 Fixing the suction pipe 3 REMOTE MOTOR INSTALLATION ...

Page 23: ...22 x2 2 1 CM 1 Passing the chains through passing the control cable through FINAL OPERATIONS ...

Page 24: ...23 V3 OK Disassembly 2 1 2 Closing the holding brackets FINAL OPERATIONS ...

Page 25: ...24 CM CE 1 V4 2 V 5 x 4 V 6 x 4 V 5 x 8 V 5 x 8 4 3 Fixing the motor or rectangular connection 3 electrical connection and tensioning the safety chains 4 FINAL OPERATIONS ...

Page 26: ...25 3 1 2 5 Repositioning of the front glass filters and side glass panels FINAL OPERATIONS ...

Page 27: ...the safety warnings indicated in this booklet It is imperative that this instructions booklet is kept together with the equipment for any future consultation If the equipment is sold or transferred to another person make sure that the booklet is also supplied so that the new user can be made aware of the hood s operation and relative warnings After the stainless steel hood has been installed it wi...

Page 28: ...used at the same time as appliances that are powered by energy other than electricity the negative pressure in the room must not exceed 4 Pa 4 x 10 5 bar HOOD WITH INTERNAL RECIRCULATION FILTERING In this model the air passes through an optional ilter unit in the ceiling to be puriied and recycled in the environment In this version the check valve must not be assembled remove it if it is on the ai...

Page 29: ... parts or parts related to the motor inside the hood with liquids or solvents For the internal metal parts see the previous paragraph METAL ANTI GREASE FILTERS It is advised to frequently wash the metal ilters at least once a month leaving them to soak in boiling water and cleaning solution for 1 hour taking care not to bend them Do not use corrosive acid or alkaline detergents Rinse them well and...

Page 30: ...uct by building materials of any kind will be required to be removed and reinstalled by the customer 10 PR Kitchens Washrooms has a service network in all metropolitan areas and most regional areas Where the warranty claim has been made outside a radius of 50km from any store where the product can be purchased the customer is responsible for the cost of delivery to the nearest service agent or the...

Page 31: ...31 NOTE NOTES ...

Page 32: ...to Treviso Italy falmec com Australia PR Kitchen Washroom Systems 83 Bangholme Rd Dandenong South VIC 3175 Australia 61 3 9700 9100 info prks com au New Zealand PR Kitchen Washroom Systems NZ P O Box 53171 Auckland Airport Auckland 2150 New Zealand 09 964 0400 info prks com nz falmec com au falmecAustralia falmecaustralia ...

Reviews: