background image

15

ENGLISH

The socket used to connect the installed equipment 

to the electrical power supply must be within reach: 

otherwise, install a mains switch to disconnect the 

hood when required.

Any changes to the electrical system must be carried 

out by a qualified electrician. 

The maximum length of the flue fastening screws 

(supplied by the manufacturer) must be 1/2" (13 mm). 

Use of non-compliant screws with these instructions 

can lead to danger of an electrical nature.

Do not try to solve the problem yourself in the event 

of equipment malfunction, but contact the Dealer or 

an authorised Servicing Department for repairs.

When installing the hood, disconnect 

the equipment by removing the plug or 

switching off the main switch.

WARNING: To Reduce The Risk Of Fire Or Electric 

Shock, Do Not Use This Fan With Any Solid-State 

Speed Control Device

WARNING: NOT SUITABLE FOR USE WITH SOL-

ID-STATE SPEED CONTROLS

FUMES DISCHARGE SAFETY

Do no connect the equipment to discharge 

pipes of fumes produced from combustion 

(for example boilers, fireplaces, etc.).

Before installing the hood, ensure that all standards in 

force regarding discharge of air out of the room have 

been complied with.

To reduce risk of fire and to properly exhaust air, 

be sure to duct air outside – Do not vent exhaust 

air into spaces within walls or ceilings or into at-

tics, crawl spaces, or garages.

WARNING: TO REDUCE THE RISK OF FIRE, USE 

ONLY METAL DUCTWORK.

USER WARNINGS

These warnings have been drawn up for 

your personal safety and those of others. 

You are therefore kindly asked to read the 

booklet carefully in its entirety before using the 

or cleaning the equipment.

The Manufacturer declines all responsibility for 

any damage caused directly, or indirectly, to per-

sons, things and pets as a consequence of failing 

to comply with the safety warnings indicated in 

this booklet.

It is imperative that this instructions booklet is 

kept together with the equipment for any future 

consultation.

If the equipment is sold or transferred to another per-

son, make sure that the booklet is also supplied so 

that the new user can be made aware of the hood's 

operation and relative warnings. 

After the stainless steel hood has been installed, it 

will need to be cleaned to remove any residues re-

maining from the protection adhesive as well as any 

grease and oil stains which, if not removed, can cause 

irreversible damage to the hood surface. To properly 

clean the unit, the manufacturer recommends using 

the supplied moist wipes, which are also available 

sold separately. 

Insist on original spare parts.

State of California Proposition 65 Warning (US 

only) 

WARNING 

This product contains chemicals known to the Sta-

te of California to cause cancer and birth defects or 

other reproductive harm. 

For more information go to www.P65Warnings.ca.gov

INTENDED USE

The equipment is solely intended to be used to 

extract fumes generated from cooking food in 

non-professional domestic kitchens: any other 

use is improper. Improper use can cause damage 

to persons, things, pets and exempts the Manu-

facturer from any liability.

The equipment can be used by children over the age 

of 8 and by persons with reduced physical, sensory 

and mental abilities, or with no experience or knowl-

edge, as long as they do so under supervision or after 

having received relative instructions regarding safe 

use of the equipment and understanding of the dan-

gers connected to it.

Children are not to play with the equipment. Clean-

ing and maintenance by the user must not be carried 

out by children without supervision.

USE AND CLEANING WARNINGS

WARNING: TO REDUCE THE RISK OF A RANGE TOP 

GREASE FIRE:

a) Never leave surface units unattended at high 

settings. Boilovers cause smoking and greasy 

spillovers that may ignite. Heat oils slowly on low 

or medium settings.

b) Always turn hood ON when cooking at high 

heat or when flambeing food (i.e. Crepes Suzette, 

Cherries Jubilee, Peppercorn Beef Flambe').

c) Clean ventilating fans frequently. Grease should 

Summary of Contents for FFPLN36I5FS-R

Page 1: ...INSTRUCTIONS BOOKLET EN MODE D EMPLOI FR MANUAL DE INSTRUCCIONES ES LIBRETTO ISTRUZIONI IT INSTRUCTIONS BOOKLET Plane island Design FFPLN36I5FS R...

Page 2: ...1 2 318 mm 10 1 8 258 mm 10 1 8 258 mm max 48 7 8 1242 mm 4 3 4 121 mm 35 3 8 898 mm 21 5 8 550 mm 68 lb 31 kg Plane Island 36 Cod FFPLN36I5FS R 120VAC 60Hz 280W 5 16 8 mm 1 8 6 mm EN tool required F...

Page 3: ...265 mm EN cable length 5 0ft 1 5m FR longueur de c ble 5 0ft 1 5m ES longueur de c ble 5 0ft 1 5m IT lunghezza cavo 5 0ft 1 5m Side outlet which can only be used with false ceiling Sortie lat rale uti...

Page 4: ...rer le rail sup rieur du rail inf rieur 1 Retrait des filtres 2 3 ES Operaciones preliminares separar la estructura superior de la estructura inferior 1 Extracci n de filtros 2 3 IT Operazioni prelimi...

Page 5: ...onaux et locaux qui remplacent toutes les recommandations stipul es dans le pr sent document ES Medidas instalaci n La altura de montaje recomendada desde la superficie de cocci n hasta el fondo de la...

Page 6: ...e 6 FR Installation au plafond sans extension de chemin e et sans rail de ixation sup rieure 6 ES Instalaci n en el techo sin extensi n de chimenea y poste superior 6 IT Installazione a soffitto senza...

Page 7: ...7 5 16 8mm x4 4 3 1 2 2 x8 1 H1 EN Trestle 7 and extension 8 assembly FR Montage support de fixation 7 et rallonge 8 ES Montaje estructura 7 y prolongaci n 8 IT Montaggio traliccio 7 e prolunga 8 7 8...

Page 8: ...hout upper trestle and without extension 9 FR Installation sur plafond sans support de fixation sup rieur et sans rallonge 9 ES Instalaci n en techo sin estructura superior y sin prolongaci n 9 IT Ins...

Page 9: ...R Montage clapet anti retour 10 tube d aspiration 11 assemblage conduit d vacuation 12 ES Montaje de v lvula de no retorno 10 tubo de aspiraci n 11 montaje de chimenea 12 IT Montaggio valvola di non r...

Page 10: ...O F F I T T O 3 V3 x4 13 14 15 EN Ceiling configuration 13 False ceiling configuration 14 15 FR Installation sur plafond 13 Installation sur faux plafond 14 15 ES Configuraci n en techo 13 Configurac...

Page 11: ...et fixation conduit d vacuation rallonge 17 ES Instalaci n c mara motor 16 conexi n el ctrica y fijaci n de chimenea prolongaci n 17 IT Installazione camera motore 16 collegamento elettrico e fissagg...

Page 12: ...nstallation au plafond sans rallonge H ni treillis T 18 19 ES Instalaci n en techo sin extensi n H y enrejado T 18 19 IT Installazione su soffitto senza prolunga H e traliccio T 18 19 EN Mandatory saf...

Page 13: ...neau 20 enlever les filtres m talliques 21 Montage du filtre en option 22 ES Procedimiento de desmontaje quite el panel 20 quite los filtros met licos 21 Montaje del filtro opcional 22 IT Procedura di...

Page 14: ...it screws and plugs supplied with the hood is only to be used on masonry walls in case of installation on walls of a different material assess other installation options keeping in mind the type of wa...

Page 15: ...booklet is kept together with the equipment for any future consultation If the equipment is sold or transferred to another per son make sure that the booklet is also supplied so that the new user can...

Page 16: ...installing the hood carefully read the chapter SAFETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technical specifications are exhibited on the labels located inside the hood POSITIONING The mini...

Page 17: ...must not be assembled remove it if it is on the air outlet fitting of the motor ASSEMBLY INSTRUCTIONS only intended for personnel qualified The hood can be installed in various configurations The gen...

Page 18: ...ease filters frequent clean ing of the filters and their supports ensures that no flammable grease is accu mulated CLEANING OF EXTERNAL SURFACES You are advised to clean the external surfaces of the h...

Page 19: ...local authorities for further information regarding the designated waste collection points nearest to you Penalties for improper disposal of such waste can be applied in compliance with national regul...

Page 20: ...contacter le Revendeur Apr s son installation aucune r clamation ne sera accept e pour des d fauts esth tiques Pendant l installation toujours utiliser des quipe ments de protection individuelle ex de...

Page 21: ...ns des espaces clos entre des murs des pla fonds ou dans des greniers des vides sanitaires ou des garages AVERTISSEMENT AFIN DE R DUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS M TALLIQUE...

Page 22: ...t appel s 4 Vous pouvez vous d fendre contre le feu en tournant le dos une sortie a D apr s le guide Kitchen Firesafety Tips pu bli par la NFPA Avant de proc der toute op ration de nettoyage ou d entr...

Page 23: ...normes de s curit ne sont pas respect es VACUATION DES FUM ES HOTTE VACUATION EXT RIEURE ASPIRANTE Dans cette version les fum es et les vapeurs sont envoy es vers l ext rieur travers un tuyau d vacua...

Page 24: ...rr t automatique apr s 15 min La fonction se d sactive LED rouge teinte si Vous appuyez une autre fois sur la touche TIMER Si vous appuyez sur la touche ON OFF Si le bo tier de commande est totalement...

Page 25: ...c est dire un D chet d rivant d quipements lectriques et lectroniques et par cons quent il ne doit pas tre jet dans la poubelle non s lective c est dire avec les d chets urbains mixtes mais il doit tr...

Page 26: ...r defectos est ticos Durante la instalaci n utilice siempre equipos de protecci n personal ej calzado de protecci n contra accidentes y adopte comportamientos prudentes y correctos El kit de fijaci n...

Page 27: ...y extraer el aire adecuadamente aseg rese de canalizar el aire al exterior No ventile el aire de escape hacia otras zonas a trav s de paredes o techos o hacia ticos s tanos o garajes ATENCI N PARA RED...

Page 28: ...espal das una salida a Basado en Kitchen Firesafety Tips publicado por NFPA Antes de realizar cualquier tipo de limpieza o de mantenimiento desconecte el equipo desenchuf ndolo o usando el interrupto...

Page 29: ...normas de seguridad DESCARGA DE HUMOS CAMPANA DE EVACUACI N EXTERNA EXTRACTORA En esta versi n los humos y vapores son canalizados hacia el ambiente exterior a trav s del tubo de descarga Para ello e...

Page 30: ...la tecla ON OFF ALARMA FILTROS Led rojo fijo off Mantenimiento de los filtros antigrasa tras unas 30 horas de uso Presione durante 3 segundos para poner a cero el contador Si el panel de mandos est t...

Page 31: ...duo de Aparatos El ctricos y Electr nicos y por tanto no se puede eliminar en la ba sura indiferenciada o sea junto con los residuos urbanos mixtos sino que se tiene que eliminar por separado siguiend...

Page 32: ...pro tezione personale es scarpe antiinfortunistiche ed adottare comportamenti prudenti e corretti Il kit di fissaggio viti e tasselli fornito con la cappa utilizzabile unicamente su pareti in muratura...

Page 33: ...zioni di pulizia sullo stesso Il Costruttore declina ogni responsabilit per eventuali danni che possano direttamente o in direttamente essere causati a persone cose ed animali domestici conseguenti al...

Page 34: ...depo siterebbero nell apparecchio compromettendone il funzionamento Parti accessibili della cappa possono essere calde se utilizzate insieme con apparecchi di cottura Non effettuare operazioni di puli...

Page 35: ...isca nel motore il numero minimo indispensabile di curve la lunghezza minima indispensabile per evitare vibrazioni e di ridurre la capa cit aspirante della cappa E necessario isolare la tubazione se p...

Page 36: ...iera completamente inattiva prima di contattare il servizio di Assistenza tecnica togliere temporaneamente circa 5 l alimentazione elettrica all elettrodomestico possibilmente agen do sull interruttor...

Page 37: ...ra indifferenziata cio insieme ai rifiuti urbani misti ma deve essere gestito separatamente cos da essere sottoposto ad ap posite operazioni per il suo riutilizzo oppure a uno specifico trattamento pe...

Page 38: ...38 NOTE NOTES...

Page 39: ...39 NOTE NOTES...

Page 40: ...Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com Codice Code Matricola Serial Number Code 110033060 Ed 01 2022...

Reviews: