background image

Manual

Digital Chlorophyll Content

Meter

clorofi

LOG

CFL2060

Revision B

05/2023

MAN_CFL2060

Summary of Contents for clorofiLOG CFL2060

Page 1: ...Manual Digital Chlorophyll Content Meter clorofiLOG CFL2060 Revision B 05 2023 MAN_CFL2060...

Page 2: ...on has been taken in the preparation of this document Falker assumes no responsibility for any errors or omissions and no liability is assumed for damages resulting from the use of the information con...

Page 3: ...7 Settings 15 3 8 Internal GPS 16 3 9 Screens 16 3 10 Falker Leaf Visualisation and data analysis 18 3 11 Data transfer 19 4 Basic maintenance 20 4 1 Battery charging 20 4 2 Device cleaning 20 4 3 Sof...

Page 4: ...nowledge of the light frequencies that chlorophyll processes best in photosynthesis With exclusive technology chlorofiLOG analyzes 3 light frequency bands in the measurement allowing a detailed analys...

Page 5: ...ment The equipament is supplied in a protection case suitable for use in the field The folowing items are provided Eletronic device CFL2060 Protection case Safety wrist strap Warranty term First use g...

Page 6: ...A to USB C Cable FLK9030 USB A output charger 3 Operation 3 1 First use To turn on the device press the on off located on the left side of the panel To turn off hold down the on off button at least f...

Page 7: ...alization screen the main screen appears The following information is displayed on this screen battery level and GPS position indication at the top Also time indication only when GPS is receiving data...

Page 8: ...r disable Bluetooth and display its status Settings menu of the device s settings All the above menu offer their own options The navigation between the menu options is done by the following buttons e...

Page 9: ...option to continue one day work or start a new day After selection the calibration screen will open Figure 7 Calibration screen To perform the calibration the chamber must remain closed for up to 6 s...

Page 10: ...urement chamber open place the leaf to be measured Keep the measurement chamber closed for 2 seconds until the equipment emits two short beeps indicating that the measurement has been performed Releas...

Page 11: ...sponding with the actual chlorophyll content existing in the leaf CAUTION For equipment conservation avoid impacts falls and exposure to rain 3 4 Data visualisation The clorofiLOG has basic resources...

Page 12: ...layed as shown in figure 13 bellow Figure 13 Viewing a point measurement The screen displays the total chlorophyll chlorophyll A and chlorophyll B results It also shows how much the total chlorophyll...

Page 13: ...screen for choosing the name of the new work will open To choose the letters use the directional arrows To confirm the letter use the enter key After choosing the name the screen for choosing the num...

Page 14: ...will have its measurements deleted The last screen is the confirmation of the action The figure below shows the chaining of screens in the delete measurements menu Figure 18 Delete measurements By cho...

Page 15: ...lowing options Figure 20 Bluetooth screen In status option it is possible to check if the bluetooth is enabled or disabled Selecting enable the bluetooth will be activated By selecting Disable bluetoo...

Page 16: ...satellites visible by the equipment because the GPS signal depends on the triangulation between satellites so that the current position is known Position accuracy will depend on signal quality The oth...

Page 17: ...CFL2060 Digital Chlorophyll Content Meter Figure 22 Device screen chaining 17 de 23...

Page 18: ...on between Web and App you can access information from anywhere for analysis or sharing It also allows the generation of measurement reports for presentation Note The Falker LEAF System for transferri...

Page 19: ...device s USB C output with the device turned off The data must then be sent to the Falker Leaf web system using a computer Windows will open a directory called CFL2BOOT where the file will be availab...

Page 20: ...ry cloth The equipment is not waterproof However it has external splash resistance and care must be taken in the region of the USB C connector If there is difficulty in calibration due to dirt in the...

Page 21: ...TION Do not attempt to update using files that you are not sure have been supplied by Falker and are suitable for your device version Attempting to update with unlisted files may lead to maintenance a...

Page 22: ...More then 20 hours of use Indications to the user LCD screen 64 x 128 pixels Sound indication Buttons 4 operation buttons 1 on off Weight 250 g with battery GPS Internal Comunication USB e Bluetooth...

Page 23: ...n for equipment CFL2060 This product contains the Bluetooth card approval code 05118 16 10070 5 4 CE and FCC marking for equipment CFL2060i This product is in conformity with the 2014 53 EU Radio Equi...

Reviews: