background image

 
 
 
 
 
3.7 GOVERNOR 

This applies to NATURAL GAS appliances only. 
The type of governor used is maintenance free. Check that blue dust cap for vent is fitted 
and in good condition. This protects the breather hole. 
Always re-check pressure at test point following governor maintenance. 
 

SECTION 4 - SPARES 

When ordering spares, always quote appliance type and serial number. This information will 
be found on data badge attached to appliance. 

 

537210660 

Burner Assembly 

537210670 

Burner Guard 

537550360 

Control Valve 

531880520 

Control Knob 

531720060 

Pilot Burner Assy Nat Gas 

537220270 

Burner Injector Nat Gas 

537220450 

Burner Injector Propane 

537220330 

Thermocouple 

531532190 

Grid Handle 

531532200 

Grid Handle Disc 

535900010 

Grid Handle & Disc set 

537210460 

Drain Cock 

534220200 

Drip Tray Assembly 

537220250 

Drip Trough Assembly 

 

Summary of Contents for STEAKHOUSE PLUS G1528

Page 1: ...ructions should be left with the Engineer in Charge for reference during servicing Further to this the Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN...

Page 2: ... Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems due to cus...

Page 3: ...removal of combustion products and cooking vapours which may be harmful to health This appliance is to be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room which they are installed The fresh air requirement for this appliance at a rate of 1M hour per kW is 13 1 M of fresh air per hour Care must be taken not to...

Page 4: ...n this appliance 1 7 TOTAL RATED HEAT INPUT Natural I2h Propane I3p Control position Kw nett Btu hr gross Kw nett Btu hr gross G1528 Full 13 1 49 000 13 1 49 000 G1528 Turndown low Per burner pair 4 9 18 400 4 9 18 400 1 8 INJECTOR SIZES NATURAL and PROPANE GAS MODEL Main Burner Nat I2h Main Burner Prop I3p X lighter Nat I2h X lighter Prop I3p G1528 4 x Amal 300 4 x Amal 110 2 x R shaw 22 2 x R sh...

Page 5: ...l Unit Unpack grill unit and check that all components are undamaged Parts supplied loose 1 off each are as specified in the contents list below Brander Drip Trough Brander Wire Grid Drip Tray Gas Governor Natural Gas Only Flue Diverter Appliance Mounting Accessories The mounting method will have been decided at time of ordering The option chosen will be supplied in a separate pack or carton GRILL...

Page 6: ...Figure 1 ...

Page 7: ...Shakeproof Washers 4 D A C B E a Fix both shelves B to end supports A C using M5 screws provided b Fix front skirt D to end supports A C using M5 screws provided c Screw adjustable feet into sockets in end supports and level stand d Lift grill upon stand Secure using four M6 screws provided through holes in front skirt and end support lugs e Holes are provided in stand foot pads to facilitate floo...

Page 8: ...racket against wall in desired position Ensure top surface is horizontal in both directions Use bracket as a template to mark fixing hole positions Drill and plug wall to accommodate fixture of bracket Having secured bracket in position place unit upon it and secure by locating base holes Secure through bracket into base of grill Diverter prevents droplets falling into burner NO FLUE DIVERTER FITT...

Page 9: ...ace test point sealing screw ensuring a gas tight joint is made Re assemble all panels and components removed during installation and commissioning Also place drip tray wire grid flue diverter and brander plate in position 2 6 INSTRUCTION TO USER Hand over user instructions and ensure that operator understands the procedure for lighting cleaning and correct use of the grill Point out location of t...

Page 10: ... slightly at rear and withdraw rearward from front locating pins Replace in reverse order To remove RH side undo two top and bottom fixings and withdraw 3 2 4 Rear Panel and Chamber a Remove top panel as detailed in Section 3 2 3 b Undo internal top fixings and those in lower exterior to remove outer panel c The lower inner panel will slide out toward rear d Replace in reverse order 3 3 BURNERS 3 ...

Page 11: ...lean with a soft rag Also clean mating surfaces in control body Sparingly re grease plug with an approved heat resistant grease Re assemble in reverse order taking care with central pin assembly Fit spring to pin first then brass washer and finally sealing washer Ensure sealing washer fits snugly into recess plug bottom and when re fitting operating spindle that niting pin engages in plug slot 3 6...

Page 12: ...spares always quote appliance type and serial number This information will be found on data badge attached to appliance 537210660 Burner Assembly 537210670 Burner Guard 537550360 Control Valve 531880520 Control Knob 531720060 Pilot Burner Assy Nat Gas 537220270 Burner Injector Nat Gas 537220450 Burner Injector Propane 537220330 Thermocouple 531532190 Grid Handle 531532200 Grid Handle Disc 53590001...