30
9. Technical Data
THE COOKER IS CATEGORY:
II2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER:
Please leave these instructions with the user.
DATA BADGE LOCATION:
Inside base drawer of cavity.
COUNTRY OF DESTINATION:
GB, IE, FR, NL, DE, SE, CH, AT, BE, LU.
Connections
Gas
Electric
Natural gas
20 mbar
230 / 400 V 50 Hz
Butane
29 mbar
Propane
37 mbar
See the appliance badge for test pressures.
Dimensions
Overall height
minimum 905 mm
maximum 925 mm
Overall width
900 mm; see
‘Positioning of Cooker’
Overall depth
650 mm
Minimum space above hotplate
800 mm
Ratings
Oven
Full
Divided
Fan element
3.31 kW
1.65 kW
Top element
3.49 kW
1.75 kW
Browning element
2.11 kW
1.06 kW
Bottom element
1.38 kW
0.69 kW
Hotplate
Bypass Screw*
Natural Gas 20 mb
L.P. Gas
Injector
Injector
Wok burner
57
3.5 kW
internal 78
3.5 kW (246 g/h)
internal 53
external 126
external 82
Large burner
40
3.0 kW
134
3.0 kW (210 g/h)
87
Medium burner
32
1.7 kW
109
1.7 kW (119 g/h)
68
Small burner
28
1.0 kW
75
1.0 kW (70 g/h)
51
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiency
Energy efficiency class on a scale of A (more efficient) to G (less efficient)
A
Energy consumption based on standard load
0.99 kWh
Usable volume (litres)
115
Size
Large
Time to cook standard load
44 mins
Surface area of grid
2400 cm²
Maximum total electric load 230 V
(Including oven fans, lights, etc.): 3.6 kW.