5
When programmed as Disabled: The siren will chirp, hazard lights will flash 3 times and LED will
show 3 flashes if the door, boot or bonnet is not closed properly. When the system enters
armed mode the violated zone will be bypassed but all other areas will remain protected.
When programmed as 15 or 40 seconds: If the door, boot or bonnet is not closed properly the
siren will chirp, hazard lights will flash 3 times and the LED will show 3 flashes. 15 or 40
seconds later the system enters armed mode and the violated zones will be bypassed but all
other areas will remain protected.
10) Auto rearm: Factory default = Disabled
If Auto Rearm is Enabled, the system will be armed again 30 seconds after the system is
disarmed if a door is not opened. Opening a door after disarming the system will disable Auto
rearm function.
11) Anti-Hijacking Delay: Factory default = 15 Sec.
The system will enter anti-hijacking mode 15 or 60 seconds after the anti-hijacking is activated
by pressing the remote control or opening the door while the ignition is on.
12) Anti-hijacking by remote control: Factory default = Disabled
When programmed as Enabled Anti-Hijacking mode can be started by pressing button 3 on the
remote control
13) Anti-hijacking by door opening: Factory default = Disabled
When programmed as Enabled: The anti-hijacking mode will be activated by opening a door
with the ignition on.
14) Turbo timer: Factory default = Disabled
When programmed as 120 or 180 Secs: The ignition will keep on running for 120 or 180
seconds after turning the ignition key off and closing the door.
Operation is as follows:
- With the ignition key still in on position
- Pull up the handbrake
- Turn the ignition key to the off position
- The Ignition and ACC circuits will stay on
- The system will then start the 120 or 180 seconds countdown
- Open and close the door
- The Ignition and ACC circuits will stay on
- After 120 or 180 seconds, the ignition and ACC circuits will be turned off automatically.
- Pressing button 1 during the 120 or 180 seconds will arm the system (Press buttons 1+2 for
Mute Arm)
* The turbo time will be functional only when the engine has been running for at least 5 minutes
15) Car type: Factory default = Automatic
Select Automatic for vehicles with automatic transmission or select manual for vehicles
with a manual transmission.
16) Remote start conditions: Factory default = Arm
When programmed as Arm: The remote start feature will be functional only when the system is
armed.
When programmed as Normal: The remote start feature will be functional when the system is
armed or disarmed mode.
17) Lock/Unlock with remote start: Factory default: Disabled
When programmed as Disabled: The doors will not lock or unlock before and after the remote
engine starter operates.
When programmed as Enabled: If the system is armed: The doors lock once before and after
remote starting the engine.