Falcon L 540 720 Instruction Manual Download Page 3

12

GB

RECOMMENDATIONS AND SUGGESTIONS

INSTALLATION

•  The manufacturer will not be held liable for any damages 

resulting from incorrect or improper installation.

•   The minimum safety distance between the cooker top and the 

extractor hood is 650 mm.

•   Check that the mains voltage corresponds to that indicated 

on the rating plate 

fi

 xed to the inside of the hood.

•   For Class I appliances, check that the domestic power supply 

guarantees adequate earthing.

    Connect the extractor to the exhaust 

fl

 ue through a pipe of 

minimum diameter 120 mm. The route of the 

fl

 ue must be as 

short as possible.

•   Do not connect the extractor hood to exhaust ducts carrying 

combustion fumes (boilers, 

fi

 replaces, etc.).

•  If the extractor is used in conjunction with non-electrical 

appliances (e.g. gas burning appliances), a suf

fi

 cient degree 

of aeration must be guaranteed in the room in order to pre-
vent the back

fl

 ow of exhaust gas. The kitchen must have an 

opening communicating directly with the open air in order 
to guarantee the entry of clean air. 

USE

•   The extractor hood has been designed exclusively for dome-

stic use to eliminate kitchen smells.

•   Never use the hood for purposes other than for which it has 

ben designed.

•   Never leave high naked 

fl

 ames under the hood when it is in 

operation.

•  Adjust the 

fl

 ame intensity to direct it onto the bottom of the 

pan only, making sure that it does not engulf the sides.

•   Deep fat fryers must be continuously monitored during use: 

overheated oil can burst into 

fl

 ames.

•  The hood should not be used by children or persons not 

instructed in its correct use. 

MAINTENANCE

•  Switch off or unplug the appliance from the mains supply 

before carrying out any maintenance work.

•   Clean and/or replace the Filters after the speci

fi

 ed time pe-

riod.

•   Clean the hood using a damp cloth and a neutral liquid deter-

gent. 

Summary of Contents for L 540 720

Page 1: ...Instruction Manual GB ...

Page 2: ......

Page 3: ...ee of aeration must be guaranteed in the room in order to pre vent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for dome stic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never leave hi...

Page 4: ...1 Hood Body complete with Controls Light Blower Filters 9 1 Reducer Flange ø 150 120 mm Ref Q ty Installation Components 12c 2 Screws 2 9 x 6 5 Q ty Documentation 1 Instruction Manual 1 Electric Diagram L L1 400 370 175 240 240 ø150 Hood Type 54 72 L 540 720 L1 512 692 12c 9 ...

Page 5: ...for a support panel thickness of between 15 mm and 30 mm Cut a fitted opening in the bottom surface of the wall unit as shown Remove the metal grease filters see par on Maintenance Disconnect the filter support by turning the internal handles provided Insert the hood until the side supports snap into place Lock in position by tightening the screws Vf from underneath the hood 375 L2 Vf Hood Type 54...

Page 6: ...g sufficient pipe clamps not supplied Remove any activated charcoal filters RECIRCULATION VERSION AIR OUTLET Drill a hole ø 120 or 150 mm in the shelf above the hood and connect the hood canopy outlet to the top part of the wall unit by means of a rigid or flexible pipe of the same diameter the choice of which is at the discretion of the installer To install a ø 120 mm air exhaust connection inser...

Page 7: ...ushed for about 2 seconds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons S1 Led Fixed Indicates that the Metal grease filters saturation alarm has been triggered and the filters need to be washed The alarm is triggered after 100 working hours Reset check the Maintenance paragraph Flashing indicates that the activa...

Page 8: ...eset Switch of the lights and extractor motor Press button T3 for at least 3 seconds until the leds start to flash Cleaning the filters The filters are washable and must be cleaned when led S1 flashes or at least every 2 months of operation or more frequently for particularly heavy usage Remove the filters one at a time supporting them with one hand and turning the safety knobs pull and turn Wash ...

Page 9: ...rm can be enabled on installation or at a later date Turn the Lights and the suction Motor off Disconnect the Hood using the Main switch or the double pole switch on the mains power sup ply Restore the connection by pressing and holding T1 Release the button All five LEDs are turned on Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation LED flashes twice Activated charcoal filter ...

Reviews: