38
11. Technical Data
This cooker is designed for use on Natural Gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is packed with the
cooker.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back. The serial number is repeated on the badge below the left-hand oven door opening.
COUNTRY OF DESTINATION: Australia.
Connection & Test Pressures
Gas (Rp ½ at rear right-hand side)
Electric
Natural gas
1 kPa
230 V 50 Hz
Propane
2.54 kPa
See the appliance badge for test pressures.
Dimensions
Overall height
minimum 900 mm
maximum 925 mm
Overall width
900 mm
Overall depth
600 mm (to fascia); 650 mm (over handles)
Minimum height above the hotplate
650 mm
Refer to ‘
Positioning the Cooker
’.
Ratings
Hotplate
Natural Gas 1.0 kPa
Propane 2.54 kPa
Input
Injector
Bypass
Input
Injector
Bypass
Marking
Size Ø
Marking
Marking
Size Ø
Marking
Wok burner
15.2 MJh
-1
internal 112 1.12 mm
90
15.0 MJh
-1
internal 66
0.67 mm
54
external 164 1.65 mm
external 91
0.87 mm
Large burner
12.3 MJh
-1
165
1.65 mm
80
12.0 MJh
-1
89
0.96 mm
41
Medium burner
6.2 MJh
-1
115
1.15 mm
56
6.2 MJh
-1
67
0.68 mm
33
Small burner
3.7 MJh
-1
92
0.92 mm
48
3.3 MJh
-1
48
0.50 mm
25
Gas burner inputs based on Gross Calorific Value.
Oven Efficiency
Ovens
Main oven
Tall oven
Forced air convection Forced air convection
Maximum power output @ 230 V 50 Hz
2.5 kW
2.5 kW
Energy efficiency class on a scale of A (more efficient) to G (less efficient)
A
A
Energy consumption based on standard load
0.90 kWh
0.99 kWh
Usable volume (litres)
69
66
Size
Large
Large
Time to cook standard load
38 minutes
49 minutes
Surface area of the grid
1400 cm
2
790 cm
2
Grill
2.3 kW
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 7.4 kW.
DocAUS.102-0002 - Technical data - 90DF - Prof+