Falcon G6478 Installation And Servicing Instructions Download Page 3

A

B

C

3

1

2

A pressure test point is provided on burner inlet

supply, accessible when facia panel is removed.

1.10 BURNER ADJUSTMENT
The burner has a fixed air inlet and gas injector.
NO ADJUSTMENT IS REQUIRED.
The pressure must be checked as detailed in

Section 1.9.

SECTION 2 - ASSEMBLY and

COMMISSIONING

2.1 ASSEMBLY
The oven is normally a basic freestanding unit and

when specified, a separate package of suite-ing

components are supplied. Assemble these

components as follows while referring to Figure 1.
1. Remove rear bottom screws (C) from each side.
2. Loosen cistern fixing screws (B) by approximately

three turns. Insert flange of each side extension

panel (3) behind cistern flanges until slots engage

around loose screws (B). Tighten screws (B) and

replace rear bottom screws (C) to secure side

extension panels.

3. Remove screws (A), position rear cover panel (1)

against unit rear. Replace screws (A) to secure

whilst pushing upwards to close against top panel.

4. Position rear extension panel (2) over side

extensions (3) and against rear cover panel (1).

Use screws provided to secure (2) to (1) and (3).

For all units, continue assembly as follows:-
5. Position unit and level. A levelling bolt is provided

in each foot with facility for floor fixing if required.

SUITING ASSEMBLY

6. Ensure all packing material is removed from oven

and cistern. Check also that steam vent is clear.

7. Hang shelf runners inside compartment and insert

trays or baskets.

2.2 CONNECTION TO GAS SUPPLY
The gas supply piping and connection to appliance

must be installed in accordance with the various

regulations listed on the cover of this manual.

On NATURAL GAS appliances, an adjustable

governor MUST be fitted in the supply. It is situated

behind the lower door. On appliances burning

PROPANE, a governor must NOT be fitted.

2.3 CONNECTION TO WATER SUPPLY
1. Connect water services including overflow from

cistern.

2. Turn on water, allow cistern to fill and check that

water depth within the compartment is correct

(70mm). Adjust ball arm valve if necessary.

Figure 1

Summary of Contents for G6478

Page 1: ...s should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE...

Page 2: ...lying at the time and a competent installer must be employed 1 4 GAS SUPPLY The incoming service must be of sufficient size to supply full rate without excessive pressure drop A gas meter is connected to the service pipe by the Gas Supplier Any existing meter should be checked by the Gas Supplier to ensure the meter is of adequate capacity to pass the required rate of gas for the unit in addition ...

Page 3: ...pushing upwards to close against top panel 4 Position rear extension panel 2 over side extensions 3 and against rear cover panel 1 Use screws provided to secure 2 to 1 and 3 For all units continue assembly as follows 5 Position unit and level A levelling bolt is provided in each foot with facility for floor fixing if required SUITING ASSEMBLY 6 Ensure all packing material is removed from oven and ...

Page 4: ...can be found in Section 3 Servicing 1 Ensure gas supply to appliance is turned ON 2 Check pilot gas supply to ensure there is no stoppage or blocking of the connecting tubes and pilot burner injector 3 Check position of pilot flame in relation to thermocouple This should envelop and heat 10mm of thermocouple end The thermocouple end should be at centre of flame 4 Ensure thermocouple is located fir...

Page 5: ...et from below burner 2 nuts and withdraw pilot burner assembly from appliance Undo fixings to remove pilot burner from bracket 3 4 INJECTORS 3 4 1 To Remove the Burner Injector Remove injector located inside air box of burner with a 16mm short armed spanner Note When cleaning injector orifice a soft fuse wire or wooden splint should be used METAL REAMERS MUST NOT BE USED TO AVOID ENLARGING THE ORI...

Page 6: ...hinges to door The serration in the hinges allows door to be adjusted in or out to take up slack or prevent hinge bind The catch adjustment is accomodated by adding or removing shims as appropriate 3 11 IGNITION SYSTEM FAULTS a If spark igniter does not light pilot check for a spark and gas If no spark is evident inspect electrode to ensure the ceramic is not cracked and that igniter lead is corre...

Page 7: ...G6478 STEAMING OVEN CONTROLS ...

Page 8: ...G6478 STEAMING OVEN FITMENTS ...

Page 9: ......

Reviews: