SECTION 4  - SPARE PARTS  

When ordering spare parts, always quote the   
appliance type and serial number.  

This information will be found on the data badge 
attached to the cont rols cover behind the controls 
compartment door.  

Short Spares Li st 

 

Multifunctional Gas Control

 

 

Burner Injector(s)

 

 

Burner Injector  Jet(s )

 

 

Cross Lighter  Jet(s)

 

 

Pilot Jet(s)

 

 

Thermocouple

 

 

Spark Igniter

 

 

Spark Igniter Lead

 

 

Spark Igniter Electrode

 

 

Cont rol  Thermostat

 

 

Safety  Thermostat

 

 

Microswitch

 

 

Neon Indicator 

– Red

 

 

Neon Indicator 

– Amber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for G2962

Page 1: ...D On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the Use...

Page 2: ...ater and electrical supply external to appliance Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer...

Page 3: ...ILATION This appliance must be installed in a suitably ventilated room in accordance with the regulations in force Sufficient ventilation natural or mechanical must be provided to supply adequate fres...

Page 4: ...ssure Model NATURAL PROPANE G2962 2965 15 mbar 6 in w g 35 5 mbar 14 2 in w g G2994 2995 35 mbar 14 in w g Operating pressure is measured at outlet test point located on front face of multi functional...

Page 5: ...red BLACK LIVE to terminal marked L or coloured RED Appliance must be protected by 3 amp fuse if 13 amp BS1363 plug is used Any other type of connection must be protected by 5 amp fuse at distribution...

Page 6: ...e to retain shaft key Open drop down door Remove fixings at corners of control panel bottom edge and also those in top flange Pull panel clear of appliance and carefully rest it on floor Take care not...

Page 7: ...onnection to pilot burner to remove electrode Undo connection lead to electrode Replace in reverse order ensuring connection to pilot assembly is not overtight as to crack electrode 3 6 2 Piezo Unit B...

Page 8: ...Tightness Figure 1 3 8 2 To Check Adjust appliance operating gas pressure Natural Gas Appliances Only a Refer to Figure 1 Remove screw from outlet test point and connect manometer Remove protective ca...

Page 9: ...not hold replace thermocouple If this does not correct condition replace multifunctional gas control unit 3 10 3 Checkout Multifunctional Control for complete function Put lighting sequence into oper...

Page 10: ...switch b Undo fixing securing switch bracket to lower bearing block c Remove switch and bracket assembly Disconnect wires and note respective positions for correct replacement d Undo fixings which se...

Page 11: ...riginal fixings unless direct replacements are available Replace in reverse order paying attention to note d above 3 17 DOOR SWITCH G2965 G2995 models only To Remove a Remove both control panels b Dis...

Page 12: ...attached to the controls cover behind the controls compartment door Short Spares List Multifunctional Gas Control Burner Injector s Burner Injector Jet s Cross Lighter Jet s Pilot Jet s Thermocouple...

Page 13: ...G2962 and G2994 BRATT PANS WIRING DIAGRAM...

Page 14: ...G2965 and G2995 BRATT PANS WIRING DIAGRAM...

Reviews: