Falcon G2962 Installation And Servicing Instructions Download Page 1

G2962, G2994  
Manual-tilt Bratt Pans 
G2965 and G2995 
Auto-tilt Bratt Pans 

 

INSTALLATION and SERVICING 
INSTRUCTIONS 

These appliances must be installed and serviced by a qualified person as stipulated by the  Gas Safety (Installation & 

Use) Regulations. 

IMPORTANT 

The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regula tions 

in force at the time of installation. Particular attention MUST be paid to - 

I.E.E Regulations for Electrical Installations  

Electricity At Work Regulations  

Gas Safety (Installation & Use) Regulations  

Health And Safety At Work etc. Act  

Local and National Building Regulations  

Fire Precautions Act  

Detailed recommendations are contained in Institute of 

Gas Engineers published documents: 

IGE/ UP/ 1, IGE/ UP/ 2 

BS6173 and BS5440 

These appliances have been CE-marked on the basis of compliance with the Gas Appliance Directive, EMC and Low Voltage  
Directive for the Countries, Gas Types and Pressures as stated on the data plate. 

WARNING - TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC MUST BE EARTHED.  

On completion of the installation, these instructions should be left with the Engineer -in-Charge for reference during servicing. 
Further to this, The Users Instructions should be handed over to the User, having had a demonstration of the operation and 

cleaning of the appliance.  

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COM MISSIONING 
THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE 

NEED FOR A SERVICE CALL. 

PREVENTATIVE MAINTENANCE CONTRACT 

In order to obtain maximum performance from this appliance we would recommend that a maintenance contract be arranged 
with SERVICELINE. Visits may then be made at agreed intervals to carry out adjustments and repairs. A quotation for this 
service will be given upon request to the contact numbers below. 
 

WEEE Directive Registration No. WEE/DC0059TT/PRO 

At end of appliance life, dispose of appliance and any replacement parts 
in a safe manner, via a licens ed waste handler.

 

Appliances are designed to be dismantled easily and recycling of all 
material is encouraged whenever practicable. 

 

Falcon Foodservice Equipment

 

HEAD OFFIC E A ND WORKS

 

Wallace View , Hillfoots Road, Stirling. FK9 5PY. Scotland.

 

SERVICELINE CONTACT

 

Phone: 01438 363 000 

Fax: 01438 369 900

 

 

T100723 Ref. 3 

Summary of Contents for G2962

Page 1: ...D On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the Use...

Page 2: ...ater and electrical supply external to appliance Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer...

Page 3: ...ILATION This appliance must be installed in a suitably ventilated room in accordance with the regulations in force Sufficient ventilation natural or mechanical must be provided to supply adequate fres...

Page 4: ...ssure Model NATURAL PROPANE G2962 2965 15 mbar 6 in w g 35 5 mbar 14 2 in w g G2994 2995 35 mbar 14 in w g Operating pressure is measured at outlet test point located on front face of multi functional...

Page 5: ...red BLACK LIVE to terminal marked L or coloured RED Appliance must be protected by 3 amp fuse if 13 amp BS1363 plug is used Any other type of connection must be protected by 5 amp fuse at distribution...

Page 6: ...e to retain shaft key Open drop down door Remove fixings at corners of control panel bottom edge and also those in top flange Pull panel clear of appliance and carefully rest it on floor Take care not...

Page 7: ...onnection to pilot burner to remove electrode Undo connection lead to electrode Replace in reverse order ensuring connection to pilot assembly is not overtight as to crack electrode 3 6 2 Piezo Unit B...

Page 8: ...Tightness Figure 1 3 8 2 To Check Adjust appliance operating gas pressure Natural Gas Appliances Only a Refer to Figure 1 Remove screw from outlet test point and connect manometer Remove protective ca...

Page 9: ...not hold replace thermocouple If this does not correct condition replace multifunctional gas control unit 3 10 3 Checkout Multifunctional Control for complete function Put lighting sequence into oper...

Page 10: ...switch b Undo fixing securing switch bracket to lower bearing block c Remove switch and bracket assembly Disconnect wires and note respective positions for correct replacement d Undo fixings which se...

Page 11: ...riginal fixings unless direct replacements are available Replace in reverse order paying attention to note d above 3 17 DOOR SWITCH G2965 G2995 models only To Remove a Remove both control panels b Dis...

Page 12: ...attached to the controls cover behind the controls compartment door Short Spares List Multifunctional Gas Control Burner Injector s Burner Injector Jet s Cross Lighter Jet s Pilot Jet s Thermocouple...

Page 13: ...G2962 and G2994 BRATT PANS WIRING DIAGRAM...

Page 14: ...G2965 and G2995 BRATT PANS WIRING DIAGRAM...

Reviews: