Model
kW
Btu/hr
G2522
13.2
45,000
Model
Plaques
CENTRE
SUPPORT
END
SUPPORT
X-LIGHTING
BURNER
G2502
4
-
4
-
G2512
8
3
4
1
G2522
12
6
4
2
G2532
6
4
4
-
Model
Main Burners
X-lightingBurners
Pilot Burner
G2522
3 x Amal 380
2 x Amal 20
SIT No. 30
Model
Main Burners
X-lightingBurners
Pilot Burner
G2522
3 x Amal 140
2 x Amal 10
SIT No. 19
Gas Type
mbar
inches w.g.
Natural
15
6
Propane
37
14.8
Support
angle
Support
angle
Plaque
Plaque
Plaque
Plaque
Centre
support
Burner
Burner
Burner
Plaque
LH Support
bar
LH Support
bar
RH Support
bar
1.7 HEAT INPUTS -
Natural andPropane Gas
1.8 INJECTOR DIAMETERS -
Natural Gas
Propane Gas
1.9 SETTING PRESSURE
A spring loaded governor, supplied with the appliance
MUST BE FITTED to natural gas models.
No governor is required on propane models.
A pressure test point is accessible upon removal of
the control panel.
1.10 BURNER ADJUSTMENT
Burner Aeration
The burners are fitted with fixed injectors. Aeration is
adjustable by means of a screw, positioned at the
burner inlet.
After setting pressure, the stability of the flame cones
should be checked. If necessary, the aeration screw
should be adjusted to achieve satisfactory cross
lighting of burners on both HIGH and LOW settings.
This will also prevent yellow tipping of the flame or
lift-off.
SECTION 2 - ASSEMBLY and
COMMISSIONING
2.1 ASSEMBLY
2.1.1 Grill Unit
Unpack grill and check that all components are
undamaged. Parts supplied loose are specified in
the contents list below
Brander Drip Trough
Brander Plate
GridShelf
Drip Tray
Gas Governor (Natural Gas only)
Additionally, the necessary plaques, supports and
cross-lighting burners are supplied as follows:-
2.1.2 Appliance Mounting Accessories
Details of various mounting options can be obtained
by contacting Falcon Sales, distributor or place of
purchase.
Refer to the individual instructions supplied with the
individual means of mounting.
Adherence to positioning clearances indicated in
Section 1.2 of this manual is mandatory.
2.1.3 Assembly of Support Bars andPlaques
a) When tunit has been installed in desired location,
the centre support bars can be positioned between
the burner lugs. Similarly LH and RH plaque
supports are located between burner lugs and
support angle. See Figure 1 below.
b) With support bars in position, plaques may be
inserted by placing these upon bars as illustrated
below.
Figure 1
All manuals and user guides at all-guides.com