SECTION 1 – INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE
ADJUSTED BY THE INSTALLER
1.1
MODEL NUMBERS, NETT WEIGHTS and DIMENSIONS
MODEL
WIDTH
mm
DEPTH
mm
HEIGHT
mm
WEIGHT
kg
G2102 RANGE
900
855
870
221
G2112 OVEN
ON STAND
900
855
1310
190
G2112/2
DOUBLE TIER
900
855
1465
362
G2112 OVEN
ON LEGS
900
855
870
181
1.2
SITING
All units, other than G2112 oven on stand or legs, must be installed on a non-combustible floor. All units must be
situated on a level surface. Although the appliance feet are adjustable to facilitate levelling, the adjustment range is
limited.
A clearance of at least 150mm must be allowed from any combustible wall.
If practicable, it is recommended that a space of at least 400mm be allowed from any side wall to provide clearance
for adjusting the rear levelling bolts, and to effect the removal of the RH side panel to facilitate servicing.
A vertical clearance of 1200mm minimum must be allowed between the top edge of flue outlet and any overlying
combustible surface.
If unit is being installed as part of a suite, it is also recommended that it be positioned at the RH end to provide
unrestricted access for servicing the controls, etc. Furthermore, if installed in a suite, either central or adjacent to a
wall, with a boxed-in void at the rear, it is vitally important that the void be adequately ventilated to ensure a supply
of air to the motor cooling fan at the rear of the oven.
Important
Care must be taken not to disturb the air combustion admission and evacuation of appliances fitted with open
burners.
1.3
VENTILATION
Recommendations for Ventilation of Catering Appliances are given in BS5440 : 2. Furthermore, to ensure
sufficient room ventilation, guidance on the volume of ventilation air required for different types of catering
equipment is provided in the table above. For multiple installations the requirements for individual appliances
should be added together. Installation should be made in accordance with local and/ or national regulations applying
at the time. A competent installer MUST be employed.
The oven flue discharges vertically through the grille at the hob rear.
EQUIPMENT
VENTILATION RATE REQUIRED
m³/min
ft³/min
Range, unit type
17
600
Pastry Oven
17
600
Fryer
26
900
Grill
17
600
Steak Grill
26
900
Boiling Pan
17
600
Steamer
17
600
Sterilizing Sink
14
500
Bains Marie
11
400
Tea/Coffee Machine
8.5-14
300-500