Falcon G1006X Installation Manual Download Page 1

RZZ 293 Ref. 2

GAS CHIEFTAIN

HEAVY DUTY APPLIANCES

INSTALLATION and

SERVICING INSTRUCTIONS

These appliances must be installed and serviced by a competent person as stipulated by the Gas

Safety (Installation & Use) Regulations.

IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions and

National Regulations in force at the time of installation. Particular attention MUST be paid to -

Gas Safety ( Installation & Use ) Regulations
Health And Safety At Work etc. Act
Local and National Building Regulations
Fire Precautions Act

These appliances have been CE-marked on the basis of compliance with the Gas Appliance Directive for the

Countries, Gas Types and Pressures as stated on the data plate.

WARNING - TO PREVENT SHOCKS, ALL APPLIANCES WHETHER

GAS OR ELECTRIC, MUST BE EARTHED

On completion of the installation, these instructions should be left with the Engineer-in-Charge for reference

during servicing. Further to this, the Users Instructions should be handed over to the User, having had a

demonstration of the operation and cleaning of the appliance.

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND

COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY

RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a maintenance contract be

arranged with GFE SERVICE. Visits may then be made at agreed intervals tocarry out adjustments and

repairs. A quotation will be given upon request to the GFE SERVICE contact numbers below.

Falcon Foodservice Equipment

HEAD OFFICE AND WORKS
PO Box 37, Foundry Loan, Larbert.

Stirlingshire. Scotland. FK5 4PL
AFE SERVICE CONTACT -
PHONE - 01438 363 000 FAX - 01438 369 900

Detailed recommendations are contained in

Institute of Gas Engineers published

documents :
IGE/ UP/ 1, IGE/ UP/ 2, BS6173 and BS5440

Summary of Contents for G1006X

Page 1: ...structions should be left with the Engineer in Charge for reference during servicing Further to this the Users Instructions should be handed over to the User having had a demonstration of the operatio...

Page 2: ...ll rate without excessive pressure drop A gas meter is connected to the service pipe by the Gas Supplier An existing meter should be checked preferably by the Gas Supplier to ensure it is of adequate...

Page 3: ...1 9 INJECTOR SIZES Natural and Propane Gas 1 10 GAS PRESSURE A test point is located upon the manifold behind the control panel Solid top single and double tier oven model access is gained by removing...

Page 4: ...er resting on the front and rear sloping angles The two plates should touch at the centre Note The top surface of each plate has one lifting lug directed toward the oven centre Replace all parts in re...

Page 5: ...One service void end p a n e l n o r m a l l y contains two holes which accommodate the header pipes See Figure 5 Gas Governors An adjustable gas governor is supplied with each natural gas model Serv...

Page 6: ...s responsible understands the instructions for lighting turning off and correct use and care of the appliance It is important to ensure that the location of the gas isolating cock is made known to the...

Page 7: ...ports Remove the cast iron heat shields Disconnect the thermocouple electrode and pilot gas supply from the pilot burner Undo the fixings which secure the front end of the burner to the base and slide...

Page 8: ...he roof baffle e Gently pull the phial and capillary tube through the oven side hole and withdraw the thermostat f Remove the right angled bracket from the existing thermostat and replace it on the ne...

Page 9: ...ttention however the air breather hole should be cleaned regularly during routine maintenance Access to this area is achieved by removing the top cover The hole is located 15mm off centre and may be c...

Reviews: