1.0  APPLIANCE INFORMATION 

This appliance has been CE-marked on the basis of compliance with the relevant EU 
directives for the heat inputs, gas pressures and voltages stated on the data plate. 

 

 

 

A - 

Serial No  

B - 

Model No  

C - 

Flue Type  

D - 

Gas Category 

 

E - 

Gas Pressure 

 

F - 

Gas Type

 

G - 

Gas Rate 

 

H - 

Total Heat Input 

 

I - 

Electrical Rating  

J - 

Total Electrical Power 

 

K - 

Magnetic Field Frequency 

 

L - 

Electrical Phase Loading 

 

 

 

Summary of Contents for E9941

Page 1: ...ERIES User installation and servicing instructions FLEXI PAN E9941 Read these instructions before use T100998 Rev No 5 Published 10 01 2019 DATE PURCHASED MODEL NUMBER SERIAL NUMBER DEALER SERVICE PRO...

Page 2: ...iance and any replacement parts in a safe manner via a licensed waste handler Appliances are designed to be dismantled easily and recycling of all material is encouraged whenever practicable Dear Cust...

Page 3: ...2 SYMBOLS SCREWDRIVER SPANNER COOKING OIL GREASE WARNING SPARK IGNITION FLAME VIEWPORT ALLEN KEY IGNITER C SPANNER REMOVE DEVICE PLUG REMOVER...

Page 4: ...ssional use only and must be used by qualified persons The installer must instruct the responsible person s of the correct operation and maintenance of the appliance Unless otherwise stated parts whic...

Page 5: ...health and safety of your business you must control any risks identified in your commercial kitchen To do this you need to think about what might cause harm to people and decide whether you are taking...

Page 6: ...IONS 13 6 0 INSTALLATION 14 SITING CLEARANCES 14 6 1 ASSEMBLY 15 6 2 ELECTRIC SUPPLY CONNECTION 16 6 3 COMMISSIONING 17 6 4 SUITING 18 7 0 SERVICING 20 7 1 GASTRONORM AND SLIDE REMOVAL 21 7 2 CONTROL...

Page 7: ...elevant EU directives for the heat inputs gas pressures and voltages stated on the data plate A Serial No B Model No C Flue Type D Gas Category E Gas Pressure F Gas Type G Gas Rate H Total Heat Input...

Page 8: ...7 2 0 OPERATION 2 1 COMPONENT PARTS A Pan F Gastronorm Slide B Heat Demand Neon Amber G Gastronorm Tray C Power Neon Red H Flue Cap D Level Gauge I Runner E Plug J Plug Removal Tool...

Page 9: ...8 2 2 CONTROLS A Power Neon Red F Simmer Position B Temperature Control Knob G Steaming Position C Griddle Position D Heat Demand Neon Amber E Constant Boil Position...

Page 10: ...unexpectedly turns off the safety thermostat might have activated Call a qualified technician to carry out an investigation 2 4 USING THE APPLIANCE BOILING BRAISING 2 4 1 Before use clean the applianc...

Page 11: ...se gov uk document ref manual handling at work INDG143 International customers should default to the health and safety guidelines provided by your government body The cleaning of fryers or other produ...

Page 12: ...leaning process When rubbing stainless steel with a cloth always rub in the direction of the grain 3 1 CLEANING AND MAINTENANCE 3 1 1 Switch appliance off and cool down 3 1 2 Ensure a Gastronorm Tray...

Page 13: ...clean cloth and rub away any stubborn staining with a non abrasive pad 3 1 10 Remove Plug using the Tool to empty the water into a Gastronorm Tray 3 1 11 Clean the drain 3 1 12 Rinse pan and drain and...

Page 14: ...E MIN A 230V MAX A 230V ACTUAL A 230V kW 230V L1 9 13 10 65 10 14 2 33 L2 9 13 10 65 10 14 2 33 L3 9 13 10 65 10 14 2 33 IF ANY CURRENT IS OUT WITH THESE TOLERANCES THE CAUSE MUST BE INVESTIGATED AND...

Page 15: ...ed by the appliance data label The electrical installation and connections should meet the necessary requirements to the local electrical wiring regulations and any electrical safety guidelines We rec...

Page 16: ...EMBLY 6 1 1 Position the appliance and level using feet adjusters as shown below TAKE CARE WHEN MOVING AN APPLIANCE FITTED WITH CASTORS 6 1 2 Fix appliance to the floor using the anti tilt device as s...

Page 17: ...V 3N for all variants Live 1 Phase 1 Brown Live 2 Phase 2 Black Live 3 Phase 3 Grey Neutral Blue Earth Yellow Green Install an appropriate three phase mains supply cable rated to at least 80 C with a...

Page 18: ...e is 280o C 20o C 6 3 6 Switch appliance off This appliance is also provided with a terminal for connection of an external equipotential conductor This terminal is an effective electrical contact with...

Page 19: ...erature silicon sealant This can be supplied by Falcon part no 523400021 6 4 1 Before levelling and suiting units ensure the units are fully built including all accessories and castings 6 4 2 Undo the...

Page 20: ...the M5 x 40 screw supplied in the kit into one of the suiting plates as shown and then insert through the front fixing holes of both units 6 4 8 B Left hand unit Slide the penny and lock washer on to...

Page 21: ...e rear hob and tighten screw caps into position 6 4 11 Replace control panel 7 0 SERVICING BEFORE ATTEMPTING ANY MAINTENANCE ISOLATE THE APPLIANCE AT THE MAINS SWITCH AND TAKE STEPS TO ENSURE THAT IT...

Page 22: ...e gastronorm tray as section 3 1 5 7 1 2 To remove gastronorm slide push down on left hand catch as shown and push up on right hand catch 7 2 CONTROL PANEL REMOVAL 7 2 1 Remove control panel as shown...

Page 23: ...ure Control to Off Position 7 3 3 Allow unit to cool 7 3 4 Isolate unit 7 3 5 Remove Control Panel as shown in 7 2 1 7 3 6 Depress reset switch 7 3 7 Replace Control Panel taking care not to trap wire...

Page 24: ...N REMOVAL 7 4 1 Remove control panel as shown in 7 2 1 7 4 2 Remove temperature control as shown 7 4 3 Remove neon as shown above 7 5 CONTACTOR REMOVAL 7 5 1 Remove control panel as shown in 7 2 1 7 5...

Page 25: ...G THERMOSTAT REMOVAL 7 6 1 Undo bolts on louvered panel pull panel out 7 6 2 Remove bolts from safety thermostat stop bracket Thus enables bracket to sit loosely on the capillary and not attached to i...

Page 26: ...25...

Page 27: ...amp fixing screws as shown above 7 6 5 Remove the four standoffs to release the two clamping plates that hold the phial bracket in position Ensure when re fitting phial clamp fixing screws that these...

Page 28: ...27 7 6 6 The Phial bracket is now free to be removed and replaced with new operating thermostat sensor Ensure when refitted the tips of the thermostats are tight up against their stop...

Page 29: ...Y THERMOSTAT REMOVAL 7 7 1 Follow step 7 6 2 7 7 2 Undo screws on mounting rail as shown above Pull safety stat from sleeve as shown Ensure when refitted the tip of the thermostats are tight up agains...

Page 30: ...29 7 8 HEATING ELEMENTS REMOVAL 7 8 1 Follow steps 7 6 1 to 7 6 6 7 8 2 Remove the element clamping plates as shown above 7 8 3 Remove the elements as shown above...

Page 31: ...30 7 9 CIRCUIT DIAGRAMS 7 9 1 E9941Circuit diagram...

Page 32: ...31 7 10 WIRING DIAGRAMS 7 10 1 E9941 Wiring diagram...

Page 33: ...t turn ON No power to unit Check mains power is connected and turned on Safety Thermostat activated Overheating Allow plate temperature to cool below 300o C Reset safety stat as per section 7 3 Heatin...

Page 34: ...tre Element 733700003 Side Element 733700004 Contactor 734310440 Gastronorm Tray 733700009 Gastronorm Silde 733700005 Gastronorm Slide Runners Pair 733700006 Drain Plug 733700007 Plug Removal Tool 733...

Page 35: ...ATION It is recommended to have a maintenance contract with a local service provider SERVICELINE CONTACT UK only Phone 441438 363 000 Warranty Policy Shortlist For our warranty policy please go to www...