Note
When connecting to a single phase supply, the three line terminals must be connected
together using the wire links provided. It is important that the links and incoming supply cable
are connected exactly as shown in the following diagram.
1.4 ELECTRICAL RATING
The electrical loadings are as stated on the appliance data plate.
1.5 FAN UNIT
This is a unit specially developed for use in forced convection ovens. It has two fans directly
mounted on the motor shaft. The larger fan is inside the oven, the purpose being to circulate
air around the cooking space whilst the smaller externally mounted fan serves to cool the
motor.
1.6 INSTRUCTION TO USER
Hand the USER'S INSTRUCTIONS to the user or purchaser and ensure that the instructions
for the correct use and cleaning are properly understood.
The location of the electrical supply switch should be made known to the user for use in an
emergency or during cleaning.
SECTION 2 - ASSEMBLY and COMMISSIONING
Warning
Due to the appliance weight (see Section 1.1), it is recommended that when lifted manually,
that it be supported by 4 people (one at each corner).
Important
Care must be taken when lifting heavy loads and ensure that correct lifting techniques are
employed. For reference see the HSE publication, Manual Handling of Loads Regulations.
2.1 ASSEMBLY
2.1.1 Oven without Stand
a) Unpack unit and remove all loose components from oven compartment.
b) Manoeuvre oven to required position and level using the adjustable feet. Also, refer to
Section 2.1.3 if applicable.
c) Connect electricity supply.
d) Insert the shelves within the oven.
Note
Feet can be secured to floor using holes provided.
2.1.2 Oven with Stand
a) Unpack unit and stand. Remove all loose components from oven compartment.
b) Ensure the leg securing bolts are turned fully back.
c) Lift oven on to stand. If a stand is fitted with castors, these should be locked.
d) Tighten leg stand securing bolts.
e) Manoeuvre unit into position.
f) For stand on castors, fit securing chain to prevent straining the electrical cable.