Falcon E711 Installation And Servicing Instructions Download Page 3

SECTION 2 - ASSEMBLY and 

COMMISSIONING

2.1 ASSEMBLY

a) Position unit in desired location. Level feet by

loosening nuts on feet. Adjust by screwing feet

clockwise to raise corresponding corner, or anti-

clockwise to lower. Tighten nuts when correct level is

achieved.

b)  Oven is supplied with 13 amp plug, ready to connect

to mains supply.

c) After plugging in to mains, check unit operates

correctly.

2.2 INSTRUCTION TO USER

Upon completion of installation, the correct method of

operation should be demonstrated to kitchen staff.

Location of the main isolating switch should also be

indicated, to be used in event of an emegency or during

cleaning.

SECTION 3 - 
SERVICING and MAINTENANCE

Warning

BEFORE ATTEMPTING TO UNDERTAKE ANY

MAINTENANCE TASK, UN-PLUG OVEN AND TAKE

STEPS TO ENSURE THIS CANNOT BE

INADVERTENTLY SWITCHED ON.

3.1 TO REMOVE CONTROL PANEL

a) Remove top front facia to expose top control panel

fixings.

b) Remove fixings from top and bottom of control panel.

c) Replace in reverse order 

3.2 TO REMOVE REAR PANEL

a) Remove fixing screws.

b) Replace in reverse order.

3.3 TO REMOVE OVEN BACK BAFFLE

a) Remove oven shelves.

b) Raise hangers from keyhole slots to remove.

c) Slacken back baffle fixing screws.

d) Raise baffle on keyhole slots to remove.

e) Replace in reverse order.

1.1 MODEL NUMBERS, NETT WEIGHTS 

and DIMENSIONS

1.2 SITING

These models are suitable for installation upon any flat,

horizontal surface and have adjustable feet to facilitate

levelling within a limited range. Position oven in desired

location and use a suitable spanner to level.

Sufficent clearance should be left around unit to allow

turning for maintenance purposes.

1.3 ELECTRICAL SUPPLY and CONNECTION

These ovens are designed to be connected to a single

phase 230V/50hz AC supply. The unit power rating is

2.65kW. The mains lead is fitted with a moulded fused

plug to BS1363 with 13 amp fuse fitted. The mains lead

wires are coloured in accordance with the following code:

Green and Yellow           EARTH

Blue                            

NEUTRAL

Brown                           LIVE

These wires should be connected as follows:

EARTH to terminal marked E

NEUTRAL to terminal marked N

LIVE to terminal marked L

Warning - This appliance MUST be earthed!

Any replacement supply cable must be 1.5mm², cord

code designation 245 IEC 57 (Cenelec H05 RN-F).               

For internal connection, outer sheathing must be stripped

140mm from the cable end. The Live and Neutral

conductors must be trimmed so that earth conductor is

longer by 50mm. Pass inlet cable through rear panel cord

grip and ensure cable is routed without leaving excessive

free length inside unit.

SECTION 1 - INSTALLATION

UNLESS OTHERWISE STATED, PARTS WHICH HAVE

BEEN PROTECTED BY THE MANUFACTURER 

ARE NOT TO BE ADJUSTED BY THE INSTALLER.

Model

Width

(mm)

Depth

(mm)

Height

(mm)

Weight

(kg)

E711 Oven

770

625 

(incl.

handle)

570

48