3.4.2 To Replace
In order to replace safety thermostat it will be

necessary to remove unit from its location on stand

or table. Adopt the following procedure:
a) Drain pan.
b) Remove control panel as detailed in Section 3.1.
c) Disconnect supply connections and remove unit

from its location to enable it to be turned on its

side later.

d) Remove element as detailed in Section 3.3.
e) Remove cover plate on element hinge block

through which capillary tube passes. Manoeuvre

capillary tube and phial through moving hinge

tube.

f) From front, remove two fixings that secure the

base plate and remove the plate.

g)

Turn the appliance on to its side and remove

safety thermostat from mounting bracket. Pull off

connections.

h) Feed capillary tube and phial through hole in base

of hinge block and remove the thermostat.

j) Replace thermostat in reverse order, taking care

that capillary tube is well clear of element

terminals.

k) Replace elements (see Section 3.3). Also replace

base panel and the control panel.

m) Fill pan with oil and heat it up. Carry out installation

tests.

3.5 DRAIN VALVE - TO REMOVE
Drain pan.
Remove control panel as detailed in Section 3.1.
Undo compression fitting nut at rear of valve,

adjacent to pan (turn it clockwise).
Remove saddle clamp at front and remove valve.
Fit a new valve in reverse order. Apply a small

quantity of high melting point grease to sliding parts of

operating lever and also to circular shaped plate on

which end of spindle runs.

3.6 TILT SWITCH
Located in element terminal box, this component

should require no maintenance.