Code 39
Advanced User’s Guide
C-3
Code Parameter
I.D. #
Type
Acceptable
Input
Defaults
D0
D1
D2
Code 39
Enter 1 for On and 0 for Off.
Enable
00
On/Off
On
or
Off
Off
On
On
Minimum length
01
Value
00–50
00
00
00
Maximum length
02
Value
01–50
01
50
20
Enable checksum
03
On/Off
On
or
Off
Off
Off
Off
Send checksum
04
On/Off
On
or
Off
Off
Off
Off
Full ASCII mode
05
On/Off
On
or
Off
Off
On
On
Interleaved 2 of 5
Enter 1 for On and 0 for Off.
Enable
08
On/Off
On
or
Off
Off
On
On
Minimum length
09
Value
02–50
02
02
06
Maximum length
0A
Value
02–50
02
50
10
Enable checksum
0B
On/Off
On
or
Off
Off
Off
Off
Send checksum
0C
On/Off
On
or
Off
Off
Off
Off
Use lengths 6 and 14 only
(case code)
0D
On/Off
On
or
Off
Off
Off
Off
Matrix 2 of 5
Enter 1 for On and 0 for Off.
Enable
10
On/Off
On
or
Off
Off
On
Off
Minimum length
11
Value
01–50
01
01
06
Maximum length
12
Value
01–50
01
50
10
Enable checksum
13
On/Off
On
or
Off
Off
Off
Off
Send checksum
14
On/Off
On
or
Off
Off
Off
Off
Standard 2 of 5
Enter 1 for On and 0 for Off.
Enable
15
On/Off
On
or
Off
Off
On
Off
Minimum length
16
Value
01–50
01
01
06
Maximum length
17
Value
01–50
01
50
10
Enable checksum
18
On/Off
On
or
Off
Off
Off
Off
Send checksum
19
On/Off
On
or
Off
Off
Off
Off
Use 2-bar start/stop
1A
On/Off
On
or
Off
Off
Off
Off
advuser.book Page 3 Friday, September 27, 2002 4:22 PM