![Falcon Dominator Plus User, Installation And Servicing Instructions Download Page 12](http://html1.mh-extra.com/html/falcon/dominator-plus/dominator-plus_user-installation-and-servicing-instructions_3263033012.webp)
12
Electric Supply & Connection
The location of the electrical connection is shown in “Dimensions/Electrical Connection
Location” Chapter. The appliance is suitable for AC supplies only. The standard terminal
arrangement is: 3 phase & neutral 5 wire connection (400V 3N~)
Phase 1
Phase 2
Phase 3
Neutral
Earth
BROWN
BLACK
GREY
BLUE
GREEN/YELLOW
IF THE CABLE IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON
. A suitably rated isolating switch with contact
separation of at least 3mm in all poles must be installed and wiring executed
in accordance with relevant regulations. Access to mains terminal block is
gained by removing the control panel.
Water Supply
Connection to the water supply is via a
½” BSPP male threaded fitting at rear.
A threaded bush is supplied with the appliance
to increase the size to ¾” (If required).
Water supply pressure should not exceed 500kPa (5 bar).
Assembly
1. Position appliance and carefully level using feet adjusters as shown below.
2. Appliances with castors should be fitted with accessories supplied according to
separate instructions provided.
3. Connect appliance to electric and water supply as stated in the previous section.