background image

DOMINATOR 

PLUS

G3106 FAN ASSISTED RANGE 

CAUTION: Read the instructions before using 
this appliance 
 

INSTALLATION and SERVICING 
INSTRUCTIONS 

 

This appliance must be installed and serviced by a competent person as stipulated by the  Gas Safety (Installation 
& Use) Regulations. 

 

IMPORTANT 

The installer must ensure that the installation of the appliance is in conformity with these instructions  and National 
Regulations in force at the time of installation. Particular attention MUST be paid to: 

 

Gas Safety (Installation & Use) Regulations  Health And Safety At Work etc. Act 

Local and National Building Regulations  Fire Precautions Act 

Detailed recommendations are contained in  Institute of Gas Engineers published documents: 

IGE/UP1, IGE/UP/2 

BS6173 and BS5440 

 

The appliance has been CE-marked on the basis of compliance with the Gas Appliance Directive for  the Countries, 
Gas Types and Pressures as stated on the data plate. 

 

WARNING: TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC,  MUST BE EARTHED. 

On completion of the installation, these instructions should be left with the Engineer-in-Charge for reference during 
servicing. Further to this, The Users Instructions should be handed over to the User,  having had a demonstration of 
the operation and cleaning of the appliance. 

 

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING  AND 
COMMISSIONING THIS  APPLIANCE. FAILURE TO COMPLY  WITH THE SPECIFIED  PROCEDURES MAY 
RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL. 

 

PREVENTATIVE MAINTENANCE CONTRACT 

In order to obtain maximum performance from this unit we would recommend that a maintenance  contract be 
arranged with 

SERVICELINE.

 Visits may then be made at agreed intervals to carry out  adjustments and repairs. A 

quotation will be given upon request to the contact numbers below. 

 

WEEE Directive Registration No. WEE/DC0059TT/PRO   At end of unit life, dispose of appliance and 
any replacement  parts in a safe manner, via a licenced waste handler. 

nits are designed to be dismantled easily and recycling of all  material is encouraged whenever 
practicable. 

 

 

Falcon Foodservice Equipment 

HEAD OFFICE AND WORKS 

Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.   

 

 

 

 

   

T100817 Ref 7

 

SERVICELINE CONTACT 

Phone: 01438 363 000 

Fax: 01438 369 900

 

Summary of Contents for DOMINATOR PLUS G3106 Series

Page 1: ...tion these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of...

Page 2: ...ts Poor combustion caused by lack of cleaning Lubrication of moving parts Lubrication of gas cocks Cleaning adjustment of pilots Correction of gas pressure to appliance Renewing of electric cable ends...

Page 3: ...ould be taken not to disturb the air combustion admission and evacuation of open top burner models 1 3 VENTILATION Adequate ventilation must be provided to supply sufficient fresh air for combustion a...

Page 4: ...el and is identified by the following symbol and must only be used for bonding purposes 1 6 HEAT INPUTS NATURAL and PROPANE GAS kW net Btu hr gross 1 6 1 Total Inputs Model kW Btu hr G3106 41 3 155 00...

Page 5: ...pplied refer to user instructions for details Important note this should be operated on a low flame setting only 2 1 2 Flue Accessory A tall flue is available as an accessory that may be substituted f...

Page 6: ...6 Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Fixings...

Page 7: ...C 10 C If reading is outwith specified range the thermostat may be faulty In this case unit should be serviced see thermostat replacement and calibration procedure Turn gas supply to oven OFF and allo...

Page 8: ...ect gas supply after all conversion work has been completed Natural to Propane Remove governor from appliance inlet pipework Propane to Natural Fit governor to appliance inlet pipework and follow deta...

Page 9: ...s and undo fixings along underside and top Pull facia panel forward while slightly easing bottom edge upward to remove 3 2 2 To Remove Open Top Hob Components Remove pan supports and burner heads comp...

Page 10: ...ition system controller it is not replaceable Full replacement of controller is necessary 3 6 OVEN IGNITERS and ELECTRODES The oven ignition system is electronically controlled Access to ignition syst...

Page 11: ...overnor be aware that unburned gas may be vented occasionally to release pressure on diaphragm This should not be confused with a gas leak 3 11 FAULT CHECK LIST If a flame is not established on any bu...

Page 12: ...12 Circuit Diagram...

Page 13: ...13 Wiring Diagram...

Reviews: