background image

1.5 ELECTRICAL RATINGS

Electrical loading is stated below and also on data plate.

The location of mains isolating switch should be

identified for use in any event of an emergency or during

cleaning.

SECTION 2 - ASSEMBLY and 

COMMISSIONING

Note

The following information should be read as applicable to

the unit being assembled.

2.1 ASSEMBLY

a) Remove feet from bag and insert into locations on

base of unit prior to positioning.

b) Position unit and carefully level using feet adjusters

when locating upon a counter or table. If bain marie is

to be installed upon a stand, please refer to details

supplied with the accessory.

c) The unit is supplied ready to be connected to supply

mains as detailed in Sections 1.3 and 1.4.

d) Switch on to check elements, thermostat and pilot

lamps all function correctly. The red lamp lights when

power is available. The amber lamp lights when

element power is on and it will will go out when

temperature setting is reached.

e) After the satisfactory completion of unit installation,

demonstrate the method of operation to kitchen staff.

2.2 INSTRUCTION TO USER

After satisfactory installation and commissioning is

completed, please hand User Instructions to user. 

Ensure that kitchen personnel understand correct

operation and cleaning of unit and that such individuals

are aware of the mains isolating switch location.

1.1 MODEL NUMBERS, NETT WEIGHTS 

and DIMENSIONS

1.2 SITING

The unit should be installed on a table or similar surface. 

Alternatively, it may be installed upon a purpose-designed

floor-stand, supplied by Falcon. If unit is to be positioned

in close proximity to any wall, partition etc., a clearance of

25mm at the rear and sides should be observed.                   

A vertical clearance of 600mm between top of unit and

any overlying combustible surface must also be provided.

1.3 ELECTRICAL SUPPLY

The unit is suitable for single phase AC supplies only.

The standard terminal arrangement is a single phase,

3 wire connection 

(230V N~)

Phase 1 - 

Brown

Neutral - 

Blue

Earth - 

Yellow/Green

WARNING - THIS APPLIANCE MUST BE EARTHED

1.4 SUPPLY CONNECTION

A suitable mains input cable is supplied that conforms to

code designation 60245 IEC 57, cable type H07RN-F.

If cable is damaged, it must be replaced by manufacturer,

service agent or suitably qualified person.  

A suitably rated isolating switch with contact separation of

at least 3mm in all poles must be installed and wiring

executed in accordance with relevant regulations.

Access to mains terminal block is gained by removing

control panel. Refer to Section 3.1 of this document.

Model

Width

(mm)

Depth

(mm)

Height

(mm)

Weight

(kg)

E3407

400

770

890

19

SECTION 1 - INSTALLATION

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER 

ARE NOT TO BE ADJUSTED BY THE INSTALLER.

E3407 1.5kW

A @ 230 V

L

6.5