1.5 ELECTRICAL RATINGS
Electrical loading is stated below and also on data plate.
The location of mains isolating switch should be
identified for use in any event of an emergency or during
cleaning.
SECTION 2 - ASSEMBLY and
COMMISSIONING
Note
The following information should be read as applicable to
the unit being assembled.
2.1 ASSEMBLY
a) Remove feet from bag and insert into locations on
base of unit prior to positioning.
b) Position unit and carefully level using feet adjusters
when locating upon a counter or table. If bain marie is
to be installed upon a stand, please refer to details
supplied with the accessory.
c) The unit is supplied ready to be connected to supply
mains as detailed in Sections 1.3 and 1.4.
d) Switch on to check elements, thermostat and pilot
lamps all function correctly. The red lamp lights when
power is available. The amber lamp lights when
element power is on and it will will go out when
temperature setting is reached.
e) After the satisfactory completion of unit installation,
demonstrate the method of operation to kitchen staff.
2.2 INSTRUCTION TO USER
After satisfactory installation and commissioning is
completed, please hand User Instructions to user.
Ensure that kitchen personnel understand correct
operation and cleaning of unit and that such individuals
are aware of the mains isolating switch location.
1.1 MODEL NUMBERS, NETT WEIGHTS
and DIMENSIONS
1.2 SITING
The unit should be installed on a table or similar surface.
Alternatively, it may be installed upon a purpose-designed
floor-stand, supplied by Falcon. If unit is to be positioned
in close proximity to any wall, partition etc., a clearance of
25mm at the rear and sides should be observed.
A vertical clearance of 600mm between top of unit and
any overlying combustible surface must also be provided.
1.3 ELECTRICAL SUPPLY
The unit is suitable for single phase AC supplies only.
The standard terminal arrangement is a single phase,
3 wire connection
(230V N~)
Phase 1 -
Brown
Neutral -
Blue
Earth -
Yellow/Green
WARNING - THIS APPLIANCE MUST BE EARTHED
1.4 SUPPLY CONNECTION
A suitable mains input cable is supplied that conforms to
code designation 60245 IEC 57, cable type H07RN-F.
If cable is damaged, it must be replaced by manufacturer,
service agent or suitably qualified person.
A suitably rated isolating switch with contact separation of
at least 3mm in all poles must be installed and wiring
executed in accordance with relevant regulations.
Access to mains terminal block is gained by removing
control panel. Refer to Section 3.1 of this document.
Model
Width
(mm)
Depth
(mm)
Height
(mm)
Weight
(kg)
E3407
400
770
890
19
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER
ARE NOT TO BE ADJUSTED BY THE INSTALLER.
E3407 1.5kW
A @ 230 V
L
6.5