background image

G7204, G7208

and G7211 FORCED

CONVECTION OVENS

INSTALLATION and

SERVICING INSTRUCTIONS

These Appliances must be installed and serviced by a competent person as stipulated by the Gas

Safety (Installation & Use) Regulations.

IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions and

National Regulations in force at the time of installation. Particular attention MUST be paid to -

I.E.E Regulations for Electrical Installations
Electricity At Work Regulations
Gas Safety (Installation & Use) Regulations
Health And Safety At Work etc. Act
Local and National Building Regulations
Fire Precautions Act

These Appliances have been CE-marked on the basis of compliance with the Gas Appliance Directive, EMC

and Low Voltage Directive for the countries, Gas Types and Pressures as stated on the Data Plate.

WARNING - TO PREVENT SHOCKS, ALL APPLIANCES WHETHER

GAS OR ELECTRIC, MUST BE EARTHED

On completion of the installation, these instructions should be left with the Engineer-in-Charge for reference

duringservicing. Further to this, The Users Instructions should be handed over to the User, havinghad a

demonstration of the operation and cleaningof the appliance.

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND

COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY

RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be

arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out adjustments and

repairs. A quotation will be given upon request to the contact numbers below.

WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement parts

in a safe manner, via a licenced waste handler.
Units are designed to be dismantled easily and recycling of all

material is encouraged whenever practicable.

T100635 Ref. 2

Falcon Foodservice Equipment

HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT -
PHONE - 01438 363 000

FAX - 01438 369 900

Detailed recommendations are contained in

Institute of Gas Engineers published

documents :
IGE/ UP/ 1, IGE/ UP/ 2, BS6173 and BS5440

Summary of Contents for G7204

Page 1: ...icing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE...

Page 2: ...Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer...

Page 3: ...ts for in dividual appliances should be added together In stallation should be made in accordance with local and or national regulations applicable at the time A competent installer MUST be employed 1...

Page 4: ...G7211 a Unpack oven and remove gas pressure governor b Manoeuvre unit into required location Level by turning adjustable feet as required Fasten locknuts on feet 2 2 CONNECTION TO GAS SUPPLY Fit gas p...

Page 5: ...witch at Cook and Hold setting check COOK and HOLD timer works and that at end of pre set time interval selected control switches from cook to hold thermostat j With oven in HOLD mode i e hold timer a...

Page 6: ...ashers are undamaged and replace as necessary 3 5 IGNITION ELECTRODES a Remove appropriate burner as Section 3 3 b Disconnect conductor from electrode c Remove screw which secures electrode to bracket...

Page 7: ...ections to cook and hold timer are remade but not pinched 3 14 BUZZER a Drop down control panel as Section 3 2 2 b Undo nut securing buzzer to bracket c Withdraw push on terminals from both in line co...

Page 8: ...terminal block c Undo fixing nut on capacitor base and remove unit d Replace in reverse order Figure 1 3 20 OVEN DOOR SEAL REPLACEMENT Seal is fitted to front frame using countersunk screws When fitti...

Page 9: ...k which joins chain to turnbuckle Push out link and withdraw chain and rod assembly d Replace in reverse order Refer to door linkage adjustment section door linkage alignment sections and Figures 2 an...

Page 10: ...W I R I N G D I A G R A M B W 3 9 0 1 9...

Page 11: ......

Page 12: ......

Reviews: