1 INTRODUCTION

This   application   note   comprises   a   brief   description   of   the   operation   of   the 
FALCOM Smart Antenna FSA03, the Pad-Design and an application circuit.

1.1 General

The Smart Antenna operates from internal ROM.

1.2 Technical data (in brief)

The FSA03  

architecture is based on the  

UBX-G5010 single chip

  from  

u-blox

, for more 

information about this chip and the u-blox5 protocol specifications, please refer to the  
u-blox website: 

www.u-blox.com

Temperature Range: 

Operation: -40 to 85°C .

Directive: 

RoHS compliant (lead-free) and green (no halogens).

ROM: 

Output NMEA messages.

Baudrate:

9600 bps,

RMC, GGA, GSA, GSV, VTG, GLL

1.3 Signal levels

The names and position of the pads can be seen from the Pad-Design, which is 
added   in   chapter  

3

  

Schematics

.   The   NC-pins   in   this   schematic   are   not 

connected.

Pin name

Level

Function

RES

3.3 V CMOS

Input

TM

3.3 V CMOS

Output

VBATT

1.4 V – 4.8 VDC

Input

GND

0 V

-

VCC

3.3 VDC ±5 %

Input

GND

0 V

-

TX

3.3 V CMOS

Output

RX

3.3 V CMOS

Input

Table 1:  

Signal levels and their function

This confidential document is a property of FALCOM  and may not be copied or circulated without previous permission.