4
BURN-BACK (FIRE IN BURNER TUBE OR CHAMBER)
In the event of a burn-back, where the flame burns back to the jet, immediately turn the
gas supply off at the control valve on the panel. After ensuring the flame is extinguished,
wait for 1 minute and re-light the appliance in the normal manner. Should the appliance
again burn back, close the control valve and call a service technician. Do not use the
appliance again until the service technician has declared that it is safe to do so.
GAS-PRESSURE REGULATOR
This appliance requires an operating pressure of 2,8 kPa at the appliance. A suitable LPG
regulator that complies with the requirements of SANS 1237 must be installed.
IMPORTANT INFORMATION FOR THE USER
This appliance may only be installed by a registered SAQCC Gas installer
. All registered
installers are issued with a card carrying their registration number. Ask to be shown the
card before allowing the installation work to commence and make a note of the Installer
registration number. Upon completion of the installation, the installer is required to explain
the operational details of the appliance together with the safety instructions. You will be
asked to sign acceptance of the installation and be provided with a completion certificate.
You should only sign for acceptance of the installation when the installation is completed to
your satisfaction.
Note that your invoice is required in the event that you wish to make a guarantee claim.
IMPORTANT INFORMATION FOR THE INSTALLER.
This appliance may only be installed by a gas installer registered with the South African
qualification and certification committee (SAQCC). The appliance must be installed in
accordance with the requirements of SANS 10087-1for use with LPG, SANS 827 for use with
NG and any fire department regulations and/or local bylaws applicable to the area. If in
doubt, check with the relevant authority before undertaking the installation. Upon
completion of the installation you are required to fully explain and demonstrate to the user
the operational details and safety practices applicable to the appliance and the installation.
WARNING AND SAFETY INSTRUCTIONS
•
Incorrect installation, maintenance and repairs could cause harm to the user. Please
ensure repairs are carried out by an authorised Falco technician.