background image

 

 

BURN-BACK (FIRE IN BURNER TUBE OR CHAMBER) 

 

In the event of a burn-back, where the flame burns back to the jet, immediately turn the 
gas supply off at the control valve on the panel. After ensuring the flame is extinguished, 
wait for 1 minute and re-light the appliance in the normal manner. Should the appliance 
again burn back, close the control valve and call a service technician. Do not use the 
appliance again until the service technician has declared that it is safe to do so.  

GAS-PRESSURE REGULATOR 

 

This appliance requires an operating pressure of 2,8 kPa at the appliance. A suitable LPG 
regulator that complies with the requirements of SANS 1237 must be installed.  

IMPORTANT INFORMATION FOR THE USER 

 

This appliance may only be installed by a registered SAQCC Gas installer

. All registered 

installers are issued with a card carrying their registration number. Ask to be shown the 
card before allowing the installation work to commence and make a note of the Installer 
registration number. Upon completion of the installation, the installer is required to explain 
the operational details of the appliance together with the safety instructions. You will be 
asked to sign acceptance of the installation and be provided with a completion certificate. 
You should only sign for acceptance of the installation when the installation is completed to 
your satisfaction.  
Note that your invoice is required in the event that you wish to make a guarantee claim.  

IMPORTANT INFORMATION FOR THE INSTALLER. 

 

This appliance may only be installed by a gas installer registered with the South African 
qualification and certification committee (SAQCC). The appliance must be installed in 
accordance with the requirements of SANS 10087-1for use with LPG, SANS 827 for use with 
NG and any fire department regulations and/or local bylaws applicable to the area. If in 
doubt, check with the relevant authority before undertaking the installation. Upon 
completion of the installation you are required to fully explain and demonstrate to the user 
the operational details and safety practices applicable to the appliance and the installation. 

 

WARNING AND SAFETY INSTRUCTIONS 

 

 

Incorrect installation, maintenance and repairs could cause harm to the user. Please 
ensure repairs are carried out by an authorised Falco technician. 

Summary of Contents for FAL-SSGH-60

Page 1: ...1 INSTALLATION AND OPERATING MANUAL OF GAS HOB RANGE...

Page 2: ...D SAFETY INSTRUCTIONS 4 INTRODUCTION 5 CLEANING AND CARE 6 CAST IRON 6 STAINLESS STEEL 6 PLASTIC 6 GLASS 6 INSTALLATION 6 PROVISION FOR VENTILATION 6 UNPACKING THE APPLIANCE 7 INSTALLING THE HOB 7 LPG...

Page 3: ...des safety instructions proper installation and use of its functions It is important that you retain these instructions proof of purchase for future reference Due to ongoing product development Falco...

Page 4: ...required to explain the operational details of the appliance together with the safety instructions You will be asked to sign acceptance of the installation and be provided with a completion certificat...

Page 5: ...the inside cavity of your appliance matches that of the electricity supply Consult your local electrician if in doubt Do not use electrical extension cables or multi sockets when connecting your appli...

Page 6: ...by using a diluted solution of water and mild detergent with a soft cloth INSTALLATION PROVISION FOR VENTILATION The room in which the gas hob is installed should have adequate ventilation The room m...

Page 7: ...the appliance is used The packaging materials should be carefully discarded and not left within easy reach of children as they are a potential hazard INSTALLING THE HOB Please ensure that your instal...

Page 8: ...nsuring the sticky transparent section still adheres to the seal Turn the hob over and place on soft surface correctly position the seal under the edge of the hob so that the outer part of the seal pe...

Page 9: ...N The qualified LPGas certified installer will make the gas connection as per the regulations THE ELECTRICAL CONNECTION We recommend that the electrical connection be carried out by a qualified electr...

Page 10: ...icated by the small flame symbol 2 Remove the control knobs 3 Insert a small flat screwdriver into the hole at the top of the brass tap and turn the adjustment screw left or right until the flame of t...

Page 11: ...11 INJECTER REPLACEMENT TABLE...

Page 12: ...know and do not attempt to reignite for at least 1 minute NOTE Matches can be used to light the burners in the event of a power failure Keep the control knob pressed in for 1 seconds ensuring the bur...

Page 13: ...locked 2 BURNER FAILING TO IGNITE Check that the power is turned on Check that the ignitor is not coated with food spillage If the ignitor is sparking but no gas coming out Ensure the gas is turned on...

Page 14: ...ance 5 Any physical damage to the product appliance that occurred prior to delivery receipt of the product appliance will only be included in this warranty provided that it is reported together with t...