10
GAS JET REPLACEMENT TABLE
Once the Jets have been replaced, minimum gas flow rates must be adjusted:
1.
Turn on the gas supply, ignite the burners and turn the control knobs to the
minimum position as indicated by the small flame symbol.
2.
Remove the control knobs
3.
Insert a small flat screwdriver into the hole at the top of the brass tap and turn the
adjustment screw left or right until the flame of the burner is conveniently regulated
to the low position.
4.
Ensure that when quickly turning from the maximum position to the minimum
position that the flame does not extinguish.
5.
Replace the control knobs.