Falco FAL-52-BIG Instruction Manual Download Page 4

11.  Q: Why is there rust marks on my extractor? 

A: 

Stainless steel can rust if cleaned with abrasive cleaners. The chemicals inside abrasive 

cleaners react with the stainless steel and the result will be rust.

 

There are many day to day 

cleaning products in our kitchens that are abrasive cleaners and unknown to the consumer. 
Please make sure you read the instructions and if Stainless Steel is not mentioned, then do 
not use the product on Stainless steel. 
 

12.  Q: Can I extend my stainless steel chimneys if they are to short? 

A: 

Yes only on a wall mount unit. Island extractor chimneys CANNOT be extended.  Please 

make sure of your measurements before starting your installation process. Additional bottom 
chimneys are sold by Lategan & Van Biljoens in Pretoria and they are used to extend the 
chimneys on wall mount units. 
 
 

13.  Q: My extractor is blowing and not extracting? 

A: 

There are three main reasons that can cause your extractor to blow instead of extracting 

and most of the time (98%), this is caused by faulty installations. Please make sure that there 
is no obstruction on top or inside your ducting hose. Make sure the power cable is neatly 
secured inside the chimneys and make sure the power cable is not causing an obstruction on 
top of your butterfly valve. Poor workmanship and failure to secure the power cable causes 
the cable to lie on top of the butterfly valve and this will block and prevent the unit from 
extracting properly. 
Please ensure that the tape stuck over your butterfly valves in the factory is removed when 
your unit is installed. Failure to remove the tape on the two butterfly valves will result in airflow 
outlet to be restricted and this will cause the air to be returned causing the blowing of air 
instead of the extraction of air. Before booking a service call make sure you check this first to 
avoid being charged. 

(a)This is a picture of the butterfly valve closed with the tape on top: 

 

The tape should be removed when installed. Both butterfly valves open when the extractor is switched 
on: 

 

(b) Ducting hoses exceeding the 2.5meters will also have a negative effect on the extraction rate of 
your extractor fan. If you are out-venting the air and the extension of ducting hose exceeds 2.5meter 
you need to purchase an addition extraction motor that must be installed in line with the ducting hose 
to support in the extraction of the air. The longer your ducting hose the less your extraction rate will 

 

 

Summary of Contents for FAL-52-BIG

Page 1: ...Cooker Hood Instruction Manual Model no FAL 52 BIS FAL 75 BIS FAL 52 BIG FAL 75 BIG...

Page 2: ...l extractor fan Commercial usage includes but is not limited to Restaurants Coffee Shops Soup Kitchens Tuck shops Food trailers Gas braai s inside or outside your property any other form of braai and...

Page 3: ...d under the guarantee period For the full list of terms and condition of the guarantee period please read the warranty certificate supplied inside the box or in your manual You can also download it fr...

Page 4: ...power cable is neatly secured inside the chimneys and make sure the power cable is not causing an obstruction on top of your butterfly valve Poor workmanship and failure to secure the power cable cau...

Page 5: ...itional inline motor when your ducting hose is exceeding 2 5m 14 Q Parts Availability A Full range of spares are available from Lategan Van Biljoens in Pretoria www appliancesspares co za 15 Q What is...

Page 6: ...the agent will not bear any responsibility for the damage caused by inappropriate installation and usage Function and Feature 1 The cooker hood is made of high quality materials with streamlined desig...

Page 7: ...for model 75CM Pic 1 Make sure the hole edge to the cupboard edge at least 35mm distance 3 Unscrew the 4 screws on the outer glass frame panel by screwdriver pull out the light wire take down the oute...

Page 8: ...he control panel Electronic button 1 Push the low button the indicating light on and the motor runs at low speed Push it again and the motor will stop 2 Push the middle button the indicating light on...

Page 9: ...the motor works at high speed and the LED display will display 3 Go on pressing button the hood works at low speed again and it repeat low mid high low mid 4 Press button once the hood will work at th...

Page 10: ...o a dishwasher with detergent for cleaning Set the temperature at around 60 2 To protect the main body from corrosion over a long period of time the cooker hood should be cleaned with hot water plus s...

Page 11: ...ent appointed by agent for servicing Please keep the room draughty when your cooker hood and gas hob are working Do not exhaust the gas from cooker hood through the same heated flue which is for the g...

Page 12: ...n the body and the gas top too long Readjust the distance Cross ventilation too strong or too closed in the kitchen Reduce cross ventilation or open the window Exhaust pipe too long Adjust the length...

Reviews: