"RETURN ROUTE ASSIGNING" - depending on version actuator can be equipped with rain sensor input. In such case it is possible to link this actuator with other
actuators which have not rain sensor functionality. In this case it is necessary to initiate "ASSIGN" function by Controller. Standard procedure which can vary for
different controllers is:

Start "ASSIGN" function - press (1 sec) programming button on actuator without rain sensor - press (1 sec) programming button on actuator with rain sensor.

Note: For information on handling or initiation the assign function of products of another manufacturers, please read the documents of the respective
manufacturer.

"All ON or All OFF" - it is possible to define if device should respect All close (OFF) or All Open (ON) command.

Note: The description for the "All ON or All OFF" function is described in the user manual of the devices supporting this function.

"SECURITY" ZWS motors are Security Enabled products. The security provides confidential communication between nodes in network.

Note: Security Enabled Z-Wave Controller must be used in order to fully utilize ZWS.

"MANUAL OPERATING" The "Manual operating" button makes it possible to operate the motor right after connecting the power supply. Manual operating works
in sequential mode, i.e. start, stop, start in opposite direction, stop - etc.

First pressing of the button after connecting the power supply will cause the motor chain to unfold.

Second pressing the button, stops the motor.

Third pressing the button starts the motor in the opposite direction.

Note: Watch the LED showing the status of devices on the network. Blinking LED indicates the status of protection state and may mean that the control of the
device is not possible.

Node Information Frame

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The
inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send
out a Node Information Frame. To issue a NIF execute the following action:

A sinlge click on programming button sends a Node Information Frame.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.

Summary of Contents for ZWS230

Page 1: ...rt Home This device is suited for use in the region mentioned in the Quickstart section For more information about frequency regulations please refer to the frequency coverage overview at Sigma Designs Website Z Wave ensures a reliable communication by reconfirming every message two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the recei...

Page 2: ...bed below in the manual Every Z Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network Safety Warning for Mains Powered Devices ATTENTION only authorized technicians under consideration of the country specific installation guidelines norms may do works with ...

Page 3: ...result of improper motor use Any activities relating to cleaning adjustment or dismantling the motor should be preceded with disconnecting the power supply The motor cannot be washed using solvent based substances or open stream of water do not immerse in water Any repairs of the motor should be carried out by authorised service by the manufacturer Electric wires supplying electricity to the power...

Page 4: ... selected pair of buttons on the Controller using ASSOCIATE function There are different modes in which the device can be used PROTECTION used to protect a device against unintentionally control by e g a child Three levels can be set by any controller supporting this functionality Unprotected motor can be operated manually and remote as well Protection by sequence motor can be only operated manual...

Page 5: ...ting button makes it possible to operate the motor right after connecting the power supply Manual operating works in sequential mode i e start stop start in opposite direction stop etc First pressing of the button after connecting the power supply will cause the motor chain to unfold Second pressing the button stops the motor Third pressing the button starts the motor in the opposite direction Not...

Page 6: ...tion groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command typically a Basic Set Command Association Groups Group Number Maximum Nodes Description 1 5 Technical Data Dimensions 0 0650000x0 0500000x0 3600000 mm Weight 1130 gr EAN ...

Page 7: ...s actuators and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controll...

Page 8: ...ohenstein Ernstthal Germany All rights reserved www zwave eu The template is maintained by Z Wave Europe GmbH The product content is maintained by Z Wave Europe GmbH Supportteam support zwave eu Last update of the product data 2017 09 20 15 49 03 ...

Reviews: