"RETURN ROUTE ASSIGNING" - depending on version actuator can be equipped with rain sensor input. In such case it is possible to link this actuator with other
actuators which have not rain sensor functionality. In this case it is necessary to initiate "ASSIGN" function by Controller. Standard procedure which can vary for
different controllers is:
Start "ASSIGN" function - press (1 sec) programming button on actuator without rain sensor - press (1 sec) programming button on actuator with rain sensor.
Note: For information on handling or initiation the assign function of products of another manufacturers, please read the documents of the respective
manufacturer.
"All ON or All OFF" - it is possible to define if device should respect All close (OFF) or All Open (ON) command.
Note: The description for the "All ON or All OFF" function is described in the user manual of the devices supporting this function.
"SECURITY" ZWS motors are Security Enabled products. The security provides confidential communication between nodes in network.
Note: Security Enabled Z-Wave Controller must be used in order to fully utilize ZWS.
"MANUAL OPERATING" The "Manual operating" button makes it possible to operate the motor right after connecting the power supply. Manual operating works
in sequential mode, i.e. start, stop, start in opposite direction, stop - etc.
First pressing of the button after connecting the power supply will cause the motor chain to unfold.
Second pressing the button, stops the motor.
Third pressing the button starts the motor in the opposite direction.
Note: Watch the LED showing the status of devices on the network. Blinking LED indicates the status of protection state and may mean that the control of the
device is not possible.
Node Information Frame
The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The
inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send
out a Node Information Frame. To issue a NIF execute the following action:
A sinlge click on programming button sends a Node Information Frame.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.