background image

 3.5. Excluding device from the network (EXCLUDE function)

Excluding the device from the “Z-Wave” network is possible only with the use of PRIMARY 

controller (e.g. ZWK15 keyboard). In each network there is always only one primary controller and every other 
is categorized as SECONDARY. The procedure of device excluding from the network is presented in 

Figure 6

.

*) Programming error may be caused by:

failure to press the programming button within 10 seconds from the controller signaling its readiness for
excluding the device from the network; 

long distance between the controller and device being excluded.

Note !!!

 Any device which is physically removed from the network (e.g. damaged) should be deleted from the memory of  

the controller (PRIMARY, SECONDARY), that is first deleted from the pair of buttons (section 3.4) and then removed 
from  the   network  (section  3.5).   The   correct   implementation   of   the   procedures  is  to  ensure   optimal   communication  
between devices. Unplugging the device without removing it from the controller memory will result in a prolonged  
reaction time  to commands and faster depletion of the controller battery.  If it is necessary to remove  the damaged 
equipment, whose removal from the controller memory is not possible, it is desirable to reconfigure the whole network  
(all devices). Start a new network configuration from restoring the controller to the factory settings (DEFAULT function), 
then call the EXCLUDE function of devices working correctly and continue to the section 3, "Controller Programming".

Note !!! 

Moving the device within the network (e.g. socket module) it is recommended to delete it from the controller 

memory (delete it from the pair of buttons first (section 3.4) and then remove from the network (section 3.5) and then add  
it again after installation in new place of work.

11.11.15 NC818

9/16

©2012, 

FAKRO

Figure 6: Excluding device from Z-Wave network

5*

. Programming error – button 

flashing for 10 sec. as presented in 
the drawing.

4

. The controller is signalizing that the 

device has been excluded successfully 
(button lights up for 2-3 sec. as 
presented in the drawing.).

1

. Press “

In/Ex

” button twice 

within 1 sec. 

3.

 Press “P” button on the device and 

hold it for 0.5 sec.  (see Device 
Programming Manual).  

2

. The controller is signalizing its readiness 

for excluding the device from the network 
(button lights up for 10 sec. as presented in 
the drawing).

x1

x2

Note!!! 

In the newer controller version, interrupting any procedure is possible by pressing the “IN/EX” button. In the 

older version, it is necessary to wait 10 seconds until the error is signalled by the controller or reset it by removing the 
batteries.  

Summary of Contents for ZWG1

Page 1: ...SOCIATE function 6 3 3 Associating another controller with the network LEARN MODE 7 3 4 Deleting device from a pair of controller buttons DELETE function 8 3 5 Excluding device from the network EXCLUDE function 9 3 6 Restoring default settings in the controller DEFAULT function 10 3 7 Removing SECONDARY controller from the network 10 4 Technical parameters 10 5 Battery replacement 11 6 WARRANTY 12...

Page 2: ...es all devices will work at the same time The ZWG1 controller is equipped with a two way Z Wave communication radio module For communication the Z Wave module exploits radio wave frequency of 868 42 MHz In Figure 1 there is presented a general view of the ZWG1 keyboard with description of available buttons and signaling 11 11 15 NC818 2 16 2012 FAKRO Figure 1 ZWG1 keyboard Dimension ZWG1 A 80 mm B...

Page 3: ...crews driven into cylindrical plugs placed in the openings drilled earlier in the wall Mounting bracket is also designed for mounting in a standard electric can 1 Fix the holder to the wall using included screws driven into wall plugs placed in the drilled openings 2 Place the ZWG1 controller onto the holder 11 11 15 NC818 3 16 2012 FAKRO ...

Page 4: ...work section 3 5 The correct implementation of the procedures is to ensure optimal communication between devices Unplugging the device without removing it from the controller memory will result in a prolonged reaction time to commands and faster depletion of the controller battery If it is necessary to remove the damaged equipment whose removal from the controller memory is not possible it is desi...

Page 5: ...XCLUDE function and repeat the procedure of device adding to the network 11 11 15 NC818 5 16 2012 FAKRO Figure 2 Adding device to Z Wave network 3 Press P button on the device and hold it for 0 5 sec see Installation Manual 4 The controller is signalizing that the device has been successfully added to the network button lights up for 2 3 sec as presented in the drawing 1 Press In Ex button once 5 ...

Page 6: ... and repeat INCLUDE and ASSOCIATE functions 11 11 15 NC818 6 16 2012 FAKRO Figure 3 Device associating with selected pair of buttons on controller 2 The controller is signilizing readiness for associating the device with a pair of buttons on the controller buttons light up for 10 sec as presented in the drawing 4 The controller is signalizing that the device has been successfully associated button...

Page 7: ...ler already belonging to another network It is necessary to perform DEFAULT procedure with it and repeat associating with the network 11 11 15 NC818 7 16 2012 FAKRO Figure 4 Associating another controller to Z Wave network 3 The controller is signalling assigning with the network buttons light up for 10 sec as presented in the drawing 1 Press In Ex button once on the PRIMARY controller see 3 1 2 P...

Page 8: ...12 FAKRO Figure 5 Deleting device from a pair of buttons on the controllers 4 The controller is signalizing successful device deleting buttons light up for 2 3 sec as presented in the drawing 5 Programming error button flashing for 2 3 sec as presented in the drawing 1 Within 1 5 sec press In Ex 1 button twice and then the button from this pair of buttons which operates the device to be removed e ...

Page 9: ...r memory is not possible it is desirable to reconfigure the whole network all devices Start a new network configuration from restoring the controller to the factory settings DEFAULT function then call the EXCLUDE function of devices working correctly and continue to the section 3 Controller Programming Note Moving the device within the network e g socket module it is recommended to delete it from ...

Page 10: ...n restoring default settings with the use of DEFAULT function 4 Technical parameters Technical parameters Power supply CR2450 3V DC Working temperature 5O C to 40O C Working range Up to 40 m Working frequency 868 42 MHz 11 11 15 NC818 10 16 2012 FAKRO Figure 7 Restoring default settings in controller 1 Within 1 5 sec press In Ex button twice 1 and then FK button 2 once 2 The controller is signaliz...

Page 11: ...tioning for the period of 2 years assuming that the programming procedure has been performed only once Multiple device programming shortens the battery life 1 Remove the back section of the casing 2 Replace the battery with a new one 3 Reinstall the back section of the casing and screw it down in 11 11 15 NC818 11 16 2012 FAKRO ...

Page 12: ...its intended use as per user manual Damage is not a result of improperly made electrical system or atmospheric phenomena The manufacturer is not liable for damage which occurred as a result of improper use or mechanical damage In case of failure the device must be submitted for repair with a Warranty Card Defects revealed within the warranty period will be removed free of charge no longer than 14 ...

Page 13: ...11 11 15 NC818 13 16 2012 FAKRO ...

Page 14: ...11 11 15 NC818 14 16 2012 FAKRO ...

Page 15: ...11 11 15 NC818 15 16 2012 FAKRO ...

Page 16: ...FAKRO PP Sp z o o ul Węgierska 144A 33 300 Nowy Sącz Polska www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 11 11 15 NC818 16 16 2012 FAKRO ...