![Fakir RIGO Instruction Manual Download Page 9](http://html1.mh-extra.com/html/fakir/rigo/rigo_instruction-manual_539230009.webp)
9
like 45%RH. Atomosphereic air always
contains water vapor, the percentage
of which depends the meterological
conditions. The higher the temperature
is the more the air keeps water vapor.
Therefore, we use the concept of
‘‘relative humidity”. When the cold air
ins heated up to the comfort
temperature in winter, the relative
percentage of the water vapor falls
which means the relative humidity
drops. In order to keep a comfortable
and health environment at home, we
need some artificial addition of water
or water vapor to room air- that’s air
humidification.
• Ideal relative humidity levels under
different situations.
The most comfort RH for human being
45-65%RH
Ideal RH for prophylactic and curative
purpose:
40-55%RH
Computer and telecom apparatuses:
45-60%RH
Furniture and musical instrument:
40-60%RH
Library art gallery and museums:
40-60%RH
Maintenance:
In case when the water is hard which
means water contains too much
calcium and magnesium, they can
cause “white powder” problem and
give heavy scales on the surface of
water basin, transducer and inner
surface of the water tank. Scales on
the surface of transducer will unable
the unit work properly.
We recommend:
1. Use cold boiled water or distilled water.
2. Clean the transducer, water tank and
basin unit every week.
3. Change the water in water tank more
often to keep it fresh.
4. Make sure to pull out the water from
the water tank and dry the water basin
before you store the unit unused for a
long period of time.
5. Clean the whole unit, and make sure
that all parts of the unit are dried
completely before unused for longer
period of time.
HOW TO CLEAN THE FILTER
SYSTEM:
1. Take the filter system away from the
tank cover.
2. Put the filter system into the salty water
for 24 hours.
3. Take the filter system away from the
salty water; shake for several times,
clean it with clear water. Make it dry.
Pack it into a polybag. Keep it in a cool
and shady place.
How to clean the transducer:
1. Put 5-10 drops of cleaning abluent on
the surface of the transducer, wait for
2-5 minutes;
2. Brush out the scale on the surface.
3. Then use the wet soft cloth wipe the
transducer.
How to clean the basin unit:
Cleaning the water basin with soft cloth
and the cleaning abluent if there is
scale in it.
TECHNICAL DATA
Electric supply:
220-240v 50Hz
Humidify power:
30W
Water tank capacity:
3.5L
Max evaporation rate:
300ml/H
Min evaporation rate:
120ml/H
Noise level:
≤ 35dB(A)
Ozone concentration: