06
Grab the fi lter cover by the fastening, fi rmly pull with
the thumb and lift it upwards
Remove the
H.E.P.A.
fi lter case and replace it with
a new one. The
H.E.P.A.
fi lter ensures an effective
operation of the vacuum cleaner for about 1 year.
Insert the cover so that the two protrusions in the lower
part of the cover are inserted in the openings of the
vacuum cleaner body, press the fi lter cover so that
the rear fastenings snap shot on the body.
2-
3-
4-
D-H.E.P.A. OUTLET FILTER
The vacuum cleaners are equipped with an H11 outlet
fi lter
H.E.P.A.
(High Effi ciency Particulate Air). The
H.E.P.A.
fi lter has been designed to maximize its fi
ltration capability through special fi bers, which are able
to retain almost all dust particles. The H11 class determines
the permeability of a fi lter. The
H.E.P.A.
H11 fi lter
retains 95,5% of particles of 0.3 micron.
To replace the
H.E.P.A.
fi lter lift the vacuum cleaner
handle and open the accessory compartment.
1-
E-INLET FILTER
Release the upper cover fastening (12) and open the
cover.
Remove the SAFBAG dust bag module (18) from the
vacuum cleaner chamber.
Slide the inlet fi lter casing with the installed inlet fi lter
from the tracks on the back side of the vacuum cleaner
chamber.
Remove the inlet fi lter (16) from the inlet fi lter casing.
Place the new fi lter in the inlet fi lter casing (17) with
the material side directed towards the inside of the
casing.
Slide the inlet fi lter casing (17) together with the fi
lter in the tracks until stop to the previous position.
1-
2-
3-
4-
5-
6-
Always replace a damaged inlet fi lter (16)
with a brand new, original one.
ATTENTION!
Insert the SAFBAG dust bag module to the vacuum
cleaner chamber.
Close the cover by pressing it until you hear
a characteristic click – pay attention not to trap the
dust bag.
7-
8-
Wind the cord by pressing the cord rewind button
(4). While doing this hold the cord to make sure it is
not tangled and the plug does not hit the vacuum
cleaner housing.
Disconnect the telescopic tube from the nozzle or
brush.
Disconnect the telescopic tube from the hose.
Press the two side buttons on the end of the hose and
remove the hose end from the inlet opening of the
vacuum cleaner.
The vacuum cleaner may be stored vertically or
horizontally. In order to do so, insert the fastening
hook of the combination brush to the combination
brush fastener. The hose may be attached to the
vacuum cleaner, however you have to make sure that
it is not excessively bent during storing.
If necessary wipe the housing and the dust bag
container with a damp cloth (it may be soaked with
dishwashing liquid) and dry it or wipe until dry.
Do not use abrasive detergents or solvents.
3-
4-
5-
6-
7-
8-
F-End of operation cleaning and maintenance
Switch off the vacuum cleaner by pressing the
“on/off”button (7).
Unplug the appliance.
1-
2-
Each user can protect the natural environment. It is
neither difficult nor expensive. In order to do it:
put the cardboard packing into recycling paper container.
put the polyethylene (PE) bags into container for plastic.
When worn out, dispose the appliance to particular
disposal centre, because of the dangerous elements of
this appliance, which can be hazardous for natural
environment.
Please do not dispose this vacuum cleaner into domestic
waste disposal!!!
Environment Protection
Summary of Contents for clarris