FTB9000 USER MANUAL
49
2. select“edit”->“sequence file”
,
press
button to Enter the sequence file
selection screen
。
3. Turn the knob or enter a number to select the file number you want to edit
,
press
button to Enter the Edit File screen
。
4. After Enter the Edit File screen
。,
set“Length of file”to 3, press
button to
confirm
,
Automatically enter "Run Times" setting, set "Run times" to
1,press
button to confirm
,
Automatically enter "Link Sequence" setting, set
"Link sequence" to 0,press
button to confirm
,
Automatically enter the "edit
step".
5. Set “Edit Step” to 1
,
press
button to confirm
,
Automatically enter the
"Voltage" setting, set the voltage value to 60V
,
press
button to confirm
。
Set the values of "source current", "source power", "load current", "load power"
to the rated value of the device, and the value of "single step delay" to 1s as
described above. After completion, it will automatically jump to the "Edit step"
and the step number will automatically add 1 to enter the second step of editing.
6.
In turn, sets the "voltage" in step 2 to 40 v, "the source current", "power source",
"current", "power", equipment ratings, "one-step delay" is set to 1 s. After
completion, it will automatically jump to "Edit step" and the number of steps will
be automatically increased by 1 to enter the third step of editing
7. In turn, sets the "voltage" in step 3 to 20 v, other remain unchanged.After the
waveform editing is completed
,
press
button
,
Save the sequence file
。
8. According to the above "Run sequence file" introduction, call the sequence file to
run.