FOR USER
3. TECHNICAL SPECIFICAT
Model
IXCR26
IXCR
Advised pool volume (m
3
)
20~40
25
Working air temp (
)
℃
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
in Smart mode
8.5
11.0
Heating capacity (kW)
in Booster mode
10.2
13.0
C.O.P
in Smart mode
8.0
8.5
C.O.P
15.6~7.3
15.5
C.O.P at 50% speed
11.8
12.0
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
in Smart mode
6.0
7.5
Heating capacity (kW)
in Booster mode
7.0
9.0
C.O.P
in Smart mode
5.4
5.5
C.O.P
7.1~4.9
7.0
C.O.P at 50% speed
6.7
6.
Performance Condition: Air 35°C, Water 28°C, Humidity
Cooling capacity (kW)
4.5
5.8
Sound pressure at 1m dB(A)
38.5~45.5
38.6~46.9
Sound pressure of 50%
capacity at 1m dB(A)
39.5
41.3
Sound pressure at 10m dB(A)
18.5~25.5
18.6~26.9
Power supply
Rated input power(kW) at air
15°C
0.18~1.43
0.22
Rated input current(A) at air
15°C
0.78~6.2
0.96~6.
Advised water flux (m³/h)
2~4
3~4
Water pipe in-out Spec
(mm)
Net Dimension Lx WxH
(mm)
893×432×
650
893×
6
Net Weight (kg)
59
61
The values indicated are valid under ideal conditions: Pool cov
running at least 15 hours a day.
Related parameters are subject to adjustment periodically for technical improvement without further notice. For
details please refer to nameplate.
9
TECHNICAL SPECIFICATION
IXCR36
IXCR46
IXCR56
IXCR66
IXCR
5~45
30~55
40~75
50~95
65
-15~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
11.0
14.0
18.0
22.0
13.0
17.0
21.5
26.0
8.5
7.7
7.5
8.0
5.5~7.5
16.0~6.6
15.5~6.5
16.5~7.0
16.3
12.0
11.5
11.5
11.6
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
7.5
9.5
12.0
15.0
9.0
11.5
14.5
18.0
5.5
5.2
5.2
5.6
0~5.0
7.5~4.5
8.0~4.7
8.0~5.1
8.0
6.7
6.8
7.0
7.0
°C, Humidity 80%
5.8
6.7
8.2
12.0
38.6~46.9
42.0~47.7
42.9~50.8
40.8~51.2
43.3
41.3
43.7
44.5
44.4
46.4
18.6~26.9
22.0~27.7
22.9~30.8
20.8~31.2
23.3
230V/1 Ph/50Hz
2~1.8
0.26~2.56
0.31~3.08
0.38~3.53
0.46
~6.7.82
1.14~11.3
1.35~13.4
1.65~15.3
2.01
3~4
4~6
6.5~8.5
8~10
10
50
×432×
650
939×432×
650
995×432×
750
1125×429×
952
1074
61
63
70
90
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtrati
are subject to adjustment periodically for technical improvement without further notice. For
IXCR80
IXCR80T
IXCR110T
65~120
65~120
90~160
27.5
27.5
33.0
32.0
32.0
40.0
7.6
7.6
7.5
6.3~6.5
16.3~6.5
16.3~6.6
11.5
11.5
11.4
18.5
18.5
24.5
22.0
22.0
28.5
5.5
5.5
5.3
8.0~5.0
8.0~5.0
8.1~4.8
7.0
7.0
6.9
14.0
14.0
16.5
3.3~51.9
43.3~51.9
42.5~51.7
46.4
46.4
43.8
23.3~31.9
23.3~31.9
22.5~31.7
400V/3 Ph/50Hz
46~4.4
0.46~4.4
0.60~5.94
01~19.1
0.66~6.35
0.87~8.57
10~12
10~12
12~18
74×539×
947
1074×539×
947
1120×539×
947
96
99
120
ered with an isothermal cover, filtration system
are subject to adjustment periodically for technical improvement without further notice. For
Summary of Contents for TurboSilence InverX IXCR26
Page 1: ......
Page 2: ......
Page 30: ......
Page 31: ......
Page 32: ...Thank you for choosing Fairland TurboSilence heat pump Version C00Xr32...