Za korisnike
- 10 -
Model
IXCR36
IXCR46
IXCR56
IXCR66
IXCR80
IXCR80T IXCR110T
Preporučeni volumen
bazena (m3)
25~50
30~60
40~75
55~100
65~120
65~120
90~160
Radna temperatura
zraka (°C)
-15~43
Uvjeti rada: zrak 26°C, voda 26°C , vlaga 80%
Snaga grijanja (kW)
in Smart mode
11.3
14.0
18.0
22.0
27.5
27.5
35.0
Snaga grijanja (kW)
in Turbo mode
13.5
17.0
21.5
26.0
32.0
32.0
40.0
C.O.P in Smart mode
8.5
7.7
7.5
8.0
7.6
7.6
7.5
C.O.P
15.5~7.5
16.0~6.6
15.5~6.5
16.5~7.0
16.3~6.5
16.3~6.5
16.3~6.6
C.O.P at 50% speed
12.0
11.5
11.5
11.6
11.5
11.5
11.4
Uvjeti rada: zrak 15°C, voda 26°C , vlaga 70%
Snaga grijanja (kW)
in Smart mode
7.5
9.5
12.0
15.0
18.5
18.5
24.5
Snaga grijanja (kW)
in Turbo mode
9.0
11.5
14.5
18.0
22.0
22.0
28.5
C.O.P in Smart mode
5.5
5.2
5.2
5.6
5.5
5.5
5.3
C.O.P
7.0~5.0
7.5~4.5
8.0~4.7
8.0~5.1
8.0~5.0
8.0~5.0
8.1~4.8
C.O.P at 50% speed
6.7
6.8
7.0
7.0
7.0
7.0
6.9
Uvjeti rada: zrak 35°C, voda 28°C , vlaga 80%
Snaga hlađenja (kW)
5.8
6.7
8.2
12.0
14.0
14.0
16.5
Razina akustičkog tlaka
1m dB(A)
38.6~46.9 42.0~47.7 42.9~50.8
40.8~51.2
43.3~51.9
43.3~51.9
42.5~51.7
Zvučni tlak 50%
kapaciteta pri 1m dB (A)
41.3
43.7
44.5
44.4
46.4
46.4
43.8
Razina akustičkog tlaka
10m dB(A)
18.6~26.9 22.0~27.7 22.9~30.8
20.8~31.2
23.3~31.9
23.3~31.9
22.5~31.7
Električno napajanje
230V/1 Ph/50Hz
400V/3 Ph/50Hz
Naznačena ulazna snaga
(kW) na temperaturi
zraka od 15
℃
0.22~1.8
0.26~2.56 0.31~3.08
0.38~3.53
0.46~4.4
0.46~4.4
0.60~5.94
Naznačena struja
napajanja (A) na
temperaturi zraka od 15
℃
0.96~7.82 1.14~11.3 1.35~13.4
1.65~15.3
2.01~19.1
0.66~6.35
0.87~8.57
Preporučeni protok vode
(m³/h)
3~4
4~6
6.5~8.5
8~10
10~12
10~12
12~18
Dimenzije ulaznih
–
izlaznih cijevi za vodu
(mm)
50
Neto
dimenzije DxŠxV
(mm)
893×432×
650
939×432×
650
995×432×
750
1125×429×
952
1074×539×
947
1074×539×
947
126
0×539×
947
Neto težina (kg)
61
65
70
98
102
111
126
1.
Navedeneinformacije vrijede uz idealne uvjete: bazen prekriven toplinski izoliranim pokrovom, sustav
filtriranja u pogonu najmanje 15 sati dnevno.
2.
Povezani parametri podliježu periodičkim izmjenama u okviru tehničkih poboljšanja bez prethodne
obavijesti. Pojedinosti se nalaze na pločici s
informacijama.
Summary of Contents for TurboSilence InverX IXCR110T
Page 1: ...EN CZ DE HR...
Page 2: ......
Page 22: ...For installers and professionals 19 APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Page 23: ...For installers and professionals 20 APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Page 24: ...For installers and professionals 21 APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Page 32: ...For installers and professionals 29 2 APP is subject to updating without notice...
Page 33: ...EN CZ DE HR...
Page 63: ...Pro instalat ry a profesion ly EN CZ DE HR...
Page 83: ...F r Monteure und H ndler 19 Anhang 1 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 84: ...F r Monteure und H ndler 20 Anhang 2 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 85: ...F r Monteure und H ndler 21 Anhang 3 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 88: ...F r Monteure und H ndler 24 2 Registrierung der Handynummer...
Page 94: ...EN CZ DE HR...
Page 117: ...Version C12Xr32...