For installers and professionals
- 14 -
2.3.1
.
Inspection before use
Check installation of the whole heat pump and the pipe connections according to the pipe
connecting drawing;
Check the electric wiring according to the electrical wiring diagram and earthing connection;
Make sure that the main power is well connected;
Check if there is any obstacle in front of the air inlet and outlet of the heat pump
2.3.2
.
Trial
The user is advised to start the water pump before the heat pump, and turn off the heat pump before
the water pump for long life circle.
The user should start the water pump, and check for any leakage of water; Power on and press the
ON/OFF button of the heat pump, and set desired temperature in the thermostat.
In order to protect the heat pump, the heat pump is equipped with start delay function. When starting
the heat pump, the fan will start to run in 3 minutes, in another 30 seconds, the compressor will start
to run.
After pool heat pump starts up, check for any abnormal noise from the heat pump.
Check the temperature setting.
2.4. Maintenance and winterizing
2.4.1 Maintenance
The maintenance should be carried out once per year by qualified professional
technician.
Cut off power supply of the
heat pump before cleaning,
examination and repairing .
Do not touch the electronic
components until the LED
indication lights on PCB turn off.
Please clean the evaporator with household detergents or clean water, NEVER use
gasoline, thinners or any similar fuel.
Check bolts, cables and connections regularly.
2.4.2 Winterizing
In winter season when you don’t swim, please cut off power supply and drain water out of
the heat pump. When using the heat pump under 2
℃
, make sure there is always water
flow.
Important:
Unscrew the water union of inlet pipe
to let the water flow out.
When the water in machine freezes in
winter season, the titanium heat
exchanger may be damaged.