6
FOR USER
3.
TECHNICAL SPECIFICATION
Model
IDHR60
IDHR96
IDHR120
Advised pool surface (
㎡
) *
≤2
5
≤
40
≤
50
Advised room size (
㎡
) *
120
200
240
Operating air temperature (
℃
)
10~38
Capacity (l/h) (Air 30
℃,
RH 80% ) *
2.5
4.0
5.0
DER (l/h.kW) (Air 30
℃,
RH 80% ) *
4.00~3.40
4.53~4.05
4.50~3.68
Capacity (l/h) (Air 30
℃,
RH 70% ) *
2.1
3.3
4.2
DER (l/h.kW) (Air 30
℃,
RH 70% ) *
3.34~3.00
4.00~3.50
3.86~3.25
Heat recovered (kW)
2.4
3.3
4.4
Electric heater optional (kW)
2
2
2
Rated power (kW)
(Air 30
℃,
RH 80% ) *
0.11~0.73
0.17~0.99
0.22~1.36
Rated current (A)
(Air 30
℃,
RH 80% ) *
0.48~3.17
0.74~4.30
0.96~5.91
Power supply
230V/1Ph/50Hz
Sound pressure at 1 m dB(A)
35.3~45.6
35.6~46.1
35.9~46.4
Air flow (m³/h)
600
800
1000
Net dimension (mm)
850
×2
91
×8
50 1120
×2
91
×8
55 1220
×2
91
×8
55
Net weight
52
65
70
1.
The temperature of this products can only work normally within the range of 10 °C ~ 38 °C.
If it exceeds this range, the performance will not be guaranteed; please note that the
performance parameters of the dehumidifier will be different under different working
conditions;
2.
Due to the technical improvement of the product, the relevant parameters will be adjusted
by steps without
prior notice. Please refer to their nameplate for more details.