4.4.
Soft-Start Test
4.4.1.
Test Condition
Measure the soft-start waveform at maximum load with ambient, after short, after OTP.
Table 4. Test Result
Input Voltage
Soft-Start Time
120V
AC
/ 60Hz
14ms Under
240V
AC
/ 50Hz
14ms Under