© 2015 Fairchild Semiconductor Corporation
23
FEBFAN7688SJXA_CP14U306
• Rev. 1.1
9.2.
AC Trim Up & Trim Down
Test Condition:
Switch the input voltage from 90 V to 264 V or from 264 V to 90 V. The output voltages
should be normal and the output of PFC bus should be less than 450 V.
Test Results:
90 V
264 V
264 V
90 V
50% Load
50% Load
Pass
Pass
Ch1:
12Vo
, Ch2:
Iin
, Ch3:
VAC
, Ch4:
Vbulk
90 V
264 V
264 V
90 V
Figure 18.
Test Waveform of AC Trim Up & Trim Down
9.3.
Efficiency
Test Condition:
Measure input current Power Factor (PF) and Total Harmonic Distortion (THD, Class D)
at various line and output loading.
Test Results:
Input
Watts
(W)
Output Watts (W)
12V
FAN
Efficiency
Standard
12V1
12V2
12Vsb
When V
IN
= 115 V,
at 100% Load
344.00
152.31
152.28
6.00
ON
90.28%
> 89%
When V
IN
= 115 V,
at 50% Load
167.30
76.37
76.39
3.01
OFF
93.10%
> 92%
When V
IN
= 115 V,
at 20% Load
69.00
30.63
30.67
1.21
OFF
90.59%
> 90%
When V
IN
= 230 V,
at 100% Load
336.80
152.31
152.31
6.00
ON
92.22%
> 91%
When V
IN
= 230 V,
at 50% Load
165.30
76.37
76.39
3.01
OFF
94.23%
> 94%
When V
IN
= 230 V,
at 20% Load
68.50
30.63
30.66
1.21
OFF
91.24%
> 90%