IS-10000063
Litho in USA
Rev. A 11/02
To remove entrained liquids from the Dripwell, open
the Drain Plug on the bottom of the Dripwell Assembly.
The flow through the regulator and the amount of
entrained oil or water in the air determine how often you
should empty the Dripwell. For more information, see
Figure 2.
If the standard maintenance procedure
does not correct the problem, install the
service kit.
MAINTENANCE
Troubleshooting
Figure 2.
Model 63 Exploded Drawing
Source
Problem
• If contaminated,
clean the
source.
Solution
High
Bleed
Leakage
Tighten the
Body Screw.
• Relief Pintle
• Relief Seat
Body Screw
NOTE:
Standard
• EA-19798-1
• EA-19798-2
Difficult to
Adjust
• Adjustment Screw • Lubricate the
Adjustment
Screw threads
and end.
NOTE: The presence of some diester oils in the air
lines can accelerate elastomer deteriora-
tion and decrease the life span of this unit.
Pressure Ranges
• 0.5-30 psig
• 1-60 and 2-120 psig