InvoMatic
User Manual
www.fagronlab.com
Page 1: ...InvoMatic User Manual www fagronlab com ...
Page 2: ......
Page 3: ...nd Use 4 1 Assembling the inversion arm 4 2 Setting Speed 4 3 Setting Timer 4 4 Running Mixer 4 5 Stopping Pausing Mixer 4 6 Quick Mix 4 7 Printing 4 8 Setting Time Date 4 9 Mixing volumes 5 Attention 6 Maintenance 6 1 Cleaning 6 2 Troubleshooting 6 3 Warranty 7 Transportation and Storage 4 4 5 5 5 5 5 6 6 7 7 7 8 8 9 10 10 10 10 11 11 ...
Page 4: ...pel the flow causing the particles to roll to the opposite side of the vessel therefore producing homogeneous mixtures Extra tools such as porcelain or ceramic spheres not included can be added inside of the vessels during mixing according to the proper ties of the substances being mixed to avoid particle agglomeration and provide evenly distributed parti cles in the formulation InvoMatic can oper...
Page 5: ... Supply voltage fluctuation Up to 24V 3 2 Operating Conditions 4 Functions and Use 4 1 Assembling the inversion arm 1 Remove the screws 1 and washers 2 2 Fit the stabilizer 3 push it down 3 and fit washers 2 and screws 1 3 To fit the inversion arm place the orange belt 1 over the pulley 2 4 Keep tension on the orange belt 1 and push the arm downwards onto the driveshaft 2 5 Tighten the screw with ...
Page 6: ...the SPEED button the display will flash 5 Adjust the speed by using the UP and DOWN buttons 6 Once the desired speed is set press the SPEED button again to set This will stop the display flashing 4 3 Setting Timer 3 Adjust the timer by using the UP and DOWN buttons 2 Press the TIMER button the display will flash 4 Once the desired time is set press the TIMER button again to set This will stop the ...
Page 7: ...time remaining and original time setting 4 5 Stopping Pausing Mixer 1 Press the STOP button to pause the mixing cycle 3 To stop the mixer and reset the timer to the original setting wait until the rotation stops and press the STOP button a second time 2 To resume mixing press the RUN button 4 6 Quick Mix 1 With the mixer in a stationary position press the QUICK MIX button 2 The mixer will run for ...
Page 8: ...mixing cycle allow the mixer to be stationary for a minimum of 1 second 4 Press the PRINT button The display will show Printing 2 Set up the printer according to the manufacturer s instructions 3 To move to the next value use the LEFT and RIGHT buttons 4 To store the date and time press the STOP button and a buzzer will sound 1 With the mixer in the stationary position press and hold the LEFT and ...
Page 9: ... 70 70 100 1 The velcro can hold vessels from 30 mL up to 1 000 mL 2 Do not fill the vessel with more than 70 of the total capacity to allow space for the content to move during mixing 4 9 Mixing volumes ...
Page 10: ...ubleshooting for common issues with the InvoMatic If the following troubleshooting guide does not resolve the problem contact your local supplier for further assis tance Problem Possible Solution The arm is making noise when rotating Some noise is permissible different conditions will cause some different noises to happen Stop rotation turn the power switch OFF and check if the arm is attached cor...
Page 11: ... installation improper connections misuse accident or abnormal conditions of operation If the warranty has been expired Fagron will still be responsible for repair with relative charges For claims under the warranty please contact your local supplier 7 Transportation and Storage InvoMatic weighs approximately 10 kg and should only be stored on flat leveled surfaces capable of supporting the weight...
Page 12: ...Fagron BV Lichtenauerlaan 182 3062 ME Rotterdam The Netherlands T 31 88 33 11 288 F 31 88 33 11 210 www fagronlab com Together we create the future of personalizing medicine ...