background image

ENCODER LINEAL MODELO:

 

SV2AM

LINEAR ENCODER MODEL:   SV2AM

MANUAL DE INSTALACION / 

INSTALLATION MANUAL

Manual Code: 14460216
Manual Version: 1609

Fagor Automation S. Coop.

Summary of Contents for SV2AM

Page 1: ...ENCODER LINEAL MODELO SV2AM LINEAR ENCODER MODEL SV2AM MANUAL DE INSTALACION INSTALLATION MANUAL Manual Code 14460216 Manual Version 1609 Fagor Automation S Coop ...

Page 2: ......

Page 3: ...Precaución Caution SV2AM v1609 página page 1 16 ...

Page 4: ...urso de medición Measuring length G Guía máquina Machine guideway P Posición absoluta Absolute position A no golpear la cabeza contra los extremos de la regla do not run the head into the ends of the scale B marcas alineadas comienzo de CM aligned marks beginning of measuring length A B Absoluta Absolute ...

Page 5: ...SV2AM v1609 página page 3 16 mm Tolerancing ISO 8015 ISO 2768 mH 6 mm 0 2 mm Simétrico Symmetrical Dimensiones soporte Support dimensions para for CM 270 mm para for CM 570 mm para for CM 670 mm ...

Page 6: ... los agujeros para amarrar la regla El área sobreada debe estar libre de pintura Make the holes to secure the scale The shaded area must be free of paint Opciones de montaje de la regla r u rosca útil Pa par de apriete Scale mounting possibilities r u useful thread Pa tightening torque ...

Page 7: ...istrado por Fagor Código indicado para realizar pedido de unidades adicionales Exclusive material supplied by Fagor Code shown for ordering additional units SW Tamaño de la llave hexagonal Size of Allen wrench Opción cabeza con rosca Threaded head option ...

Page 8: ...de contaminación Avoid orienting the sealing lips towards pollution sources En ambientes muy contaminantes conviene proteger la regla Utilizar juntas de estanqueidad para evitar filtraciones In very polluted environments the scale should be protected Use seals to prevent filtrations Junta de estanqueidad Seal ...

Page 9: ...ORNILLOS M6 M6 SCREW MOUNTING OPTIONS Agujero central middle hole Resto de agujeros Rest of holes Cotas de montaje en página 8 Mounting dimensions on page 8 Cotas de montaje en página 9 Mounting dimensions on page 9 Premontar y alinear el soporte de la regla una vez premontada apretar los tornillos Premount and align the encoder support Once premounted tighten the bolts SV2AM v1609 página page 7 1...

Page 10: ...e fijarse en el soporte sólamente por abajo Dibujo IV La regla puede fijarse en el soporte sólamente por arriba Dibujo V The encoder may be mounted on the support from the top and bottom I II III The encoder may be mounted on the support only from the bottom IV The encoder may be mounted on the support only from the top V ...

Page 11: ...fijarse en el soporte sólamente por abajo Dibujo III La regla puede fijarse en el soporte sólamente por arriba Dibujo IV The encoder may be mounted on the support from the top and bottom I II The encoder may be mounted on the support only from the bottom III The encoder may be mounted on the support only from the top IV ...

Page 12: ...609 página page 10 16 POSIBILIDADES DE MONTAJE DE REGLA EN SOPORTE ENCODER MOUNTING POSSIBILITIES ON THE SUPPORT CON EL CONECTOR A AMBOS LADOS WITH THE CONNECTOR ON BOTH SIDES C Lado del conector Connector side ...

Page 13: ...osicionar la cabeza 4 Meter los tornillos de la cabeza y apretar 5 Quitar las piezas de embalaje de la cabeza 1 Premount the encoder leaning it on the support as per the arrow 2 Secure the encoder on the support Either from the top or from the bottom 3 Loosen the packing parts and position the reader head 4 Insert the head bolts and tighten them 5 Remove the packing parts of the reader head ...

Page 14: ... 8573 1 En montajes verticales no meter el aire por abajo When mounting vertically do not feed air from underneath Extraer prisionero antes de meter el racor de aire Remove the pin before inserting the air intake 1 Entrada de aire por los tacos posible por ambos tacos Air intake through endcaps possible through both endcaps 2 Entrada de aire por la cabeza Air intake through the reader head ...

Page 15: ...Resolución Resolution 10 nm 50 nm Longitud de cable Cable length 30 m 99 ft Radio de curvatura Bending radius Rígido Rigid Flexible Φ 6 mm 24 mm 60 mm Φ 10 mm con protección with protection 35 mm 60 mm Φ 8 mm 50 mm 64 mm Montaje rígido con fijaciones Rigid mounting with clamps Flexionado común Common bending Flexionado común Common bending ...

Page 16: ...SV2AM v1609 página page 14 16 ...

Page 17: ...era intermedia opcional XCint Intermediate extension cable optional XCint Alargadera XC Extension cable XC EC B C9 F Longitud length 1 3 m XC C8 F C9 Longitud length 5 10 15 20 25 m XC C8 MB Longitud length 5 10 15 20 25 m EC B C9 F Conector circular 17 macho con ferrita 17 pin male round connector with ferrite PIN 14 17 8 9 7 1 10 4 Carcasa Housing SEÑAL SIGNAL DATA DATA REQ REQ 5V 5V sensor 0V 0...

Page 18: ...s pueden seguir a las referencias de los modelos indicados en este manual Todos ellos cumplen con las siguientes normas Manufacturer Fagor Automation S Coop Barrio de San Andrés 19 C P 20500 Mondragón Guipúzcoa SPAIN We declare under our exclusive responsibility the conformity of the product referred to in this manual Note Some additional characters may follow the model references indicated in thi...

Page 19: ......

Page 20: ...GOR AUTOMATION S COOP Bº San Andrés Nº 19 Apdo de correos 144 20500 Arrasate Mondragón Spain Web www fagorautomation com Email info fagorautomation es Tel 34 943 719200 Fax 34 943 791712 Fagor Automation ...